ArticleTranslational vision science & technology2021
Individualized Glaucoma Change Detection Using Deep Learning Auto Encoder-Based Regions of Interest.
Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 24 citations in OpenAlex.
- Artificial intelligence in glaucoma: opportunities, challenges, and future directions.Biomedical engineering online · 2023Pooled it
- Deep learning and optical coherence tomography in glaucoma: Bridging the diagnostic gap on structural imaging.Frontiers in ophthalmology · 2022Pooled it
- Performance of OCT-Based Artificial Intelligence Models for Detecting and Predicting Glaucoma Progression: A Systematic Review.Journal of clinical medicine · 2026Review
- Artificial Intelligence in Ocular Surface Tumors: Current Advances, Challenges, and Future Directions.Diagnostics (Basel, Switzerland) · 2026Review
- Artificial Intelligence in Glaucoma: Advances in Diagnosis, Progression Forecasting, and Surgical Outcome Prediction.International journal of molecular sciences · 2025Review
- Detection of Ocular Surface Squamous Neoplasia Using Artificial Intelligence With Anterior Segment Optical Coherence Tomography.American journal of ophthalmology · 2025Article
- Artificial Intelligence for Optical Coherence Tomography in Glaucoma.Translational vision science & technology · 2025Review
- Glaucoma detection in myopic eyes using deep learning autoencoder-based regions of interest.Frontiers in ophthalmology · 2025Article
- Detection of glaucoma progression on longitudinal series of en-face macular optical coherence tomography angiography images with a deep learning model.The British journal of ophthalmology · 2024Observational
- Combining Optical Coherence Tomography and Optical Coherence Tomography Angiography Longitudinal Data for the Detection of Visual Field Progression in Glaucoma.American journal of ophthalmology · 2023Article
- Application of artificial intelligence in glaucoma care: An updated review.Taiwan journal of ophthalmologyReview
- Applications of deep learning in the analysis of optical coherence tomography images for glaucoma-related diagnostics.Taiwan journal of ophthalmologyReview
- Use of artificial intelligence in forecasting glaucoma progression.Taiwan journal of ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 4 institutions in 1 country.
Funding
Abstract
Purpose: To compare change over time in eye-specific optical coherence tomography (OCT) retinal nerve fiber layer (RNFL)-based region-of-interest (ROI) maps developed using unsupervised deep-learning auto-encoders (DL-AE) to circumpapillary RNFL (cpRNFL) thickness for the detection of glaucomatous progression. Methods: Forty-four progressing glaucoma eyes (by stereophotograph assessment), 189 nonprogressing glaucoma eyes (by stereophotograph assessment), and 109 healthy eyes were followed for ≥3 years with ≥4 visits using OCT. The San Diego Automated Layer Segmentation Algorithm was used to automatically segment the RNFL layer from raw three-dimensional OCT images. For each longitudinal series, DL-AEs were used to generate individualized eye-based ROI maps by identifying RNFL regions of likely progression and no change. Sensitivities and specificities for detecting change over time and rates of change over time were compared for the DL-AE ROI and global cpRNFL thickness measurements derived from a 2.22-mm to 3.45-mm annulus centered on the optic disc. Results: The sensitivity for detecting change in progressing eyes was greater for DL-AE ROIs than for global cpRNFL annulus thicknesses (0.90 and 0.63, respectively). The specificity for detecting not likely progression in nonprogressing eyes was similar (0.92 and 0.93, respectively). The mean rates of change in DL-AE ROI were significantly faster than for cpRNFL annulus thickness in progressing eyes (-1.28 µm/y vs. -0.83 µm/y) and nonprogressing eyes (-1.03 µm/y vs. -0.78 µm/y). Conclusions: Eye-specific ROIs identified using DL-AE analysis of OCT images show promise for improving assessment of glaucomatous progression. Translational Relevance: The detection and monitoring of structural glaucomatous progression can be improved by considering eye-specific regions of likely progression identified using deep learning.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.