Evidence map›Paper›PMID 34291295›Full record

ArticleInteractive cardiovascular and thoracic surgery2021

Single-step localization and excision of small pulmonary nodules using a mobile 3D C-arm.

Ming-Ju Hsieh, Pin-Li Chou, Hsin-Yueh Fang, Chih-Tsung Wen, Yin-Kai Chao

Erratum issued Registry-linked trialOpen access · bronzeAbstract read
In one paragraph

Article in Interactive cardiovascular and thoracic surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT05518669 (Mobile Cone-Beam CT in Combination With Electromagnetic Navigation Bronchoscopy for the Diagnosis of Peripheral Pulmonary Nodules), which is not on this map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05518669 unknown statusnot on this mapstarted 2022, after this paper: background citation

Mobile Cone-Beam CT in Combination With Electromagnetic Navigation Bronchoscopy for the Diagnosis of Peripheral Pulmonary Nodules

TypeobservationalSponsorShanghai Chest HospitalRan2022 to 2024Enrolled109ConditionsPeripheral Pulmonary Nodules, Lung CancerArmsElectromagnetic Navigation Bronchoscopy (superDimension™ Navigation System) and Mobile Cone-Beam CT (Cios Spin)
3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ming-Ju HsiehDivision of Thoracic Surgery, Chang Gung Memorial Hospital-Linkou, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Pin-Li ChouDivision of Thoracic Surgery, Chang Gung Memorial Hospital-Linkou, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Hsin-Yueh FangDivision of Thoracic Surgery, Chang Gung Memorial Hospital-Linkou, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Chih-Tsung WenDivision of Thoracic Surgery, Chang Gung Memorial Hospital-Linkou, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Yin-Kai ChaoDivision of Thoracic Surgery, Chang Gung Memorial Hospital-Linkou, College of Medicine, Chang Gung University, Taoyuan, Taiwan.ORCID 0000-0001-8649-8783
Chang Gung University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe use of a hybrid operating room equipped with robotic C-arm cone-beam computed tomography for single-step localization and excision of small pulmonary nodules finds high cost barriers. The new generation of 3D C-arm system not only depicts soft tissues with high contrast but also offers a more affordable and sustainable solution. This approach has been chiefly applied in the field of orthopedic surgery. In this case series, we describe the use of a mobile 3D C-arm system for localizing and removing small pulmonary nodules.

methodsBetween July and September 2020, we identified 14 patients who underwent localization and removal of small pulmonary nodules with a 3D C-arm system. We retrospectively reviewed clinical records to document the feasibility and safety of the procedure.

resultsThe median tumour size was 7.5 mm [interquartile range (IQR): 5 - 9.75 mm], with a median distance from the pleural surface of 4.2 mm (IQR: 0.5 - 6.45 mm). We successfully visualized all of the pulmonary lesions by intraoperative CT imaging. Localization was achieved in 13 patients, who subsequently underwent complete thoracoscopic resection. The median time required to localize lesions was 41.5 min (IQR: 33.75 - 53.25 min), with a median radiation exposure (expressed through the skin absorbed dose) of 143.45 mGy (IQR: 86.1 - 194.6 mGy). Failure to localize occurred in 1 patient because of pneumothorax caused by repeated needle puncture. All patients were successfully discharged and the median length of stay was 2.5 days (IQR: 2 - 3 days).

conclusionsThis case series demonstrates the feasibility of single-step localization and excision of small pulmonary nodules using a mobile 3D C-arm.

Indexed as

Lung NeoplasmsMultiple Pulmonary NodulesSolitary Pulmonary NoduleHumansRetrospective StudiesThoracic Surgery, Video-AssistedTomography, X-Ray Computed3D C-armLocalizationSmall pulmonary nodules

Identifiers

PMID34291295
PMCPMC8932509
OpenAlexW3186736282

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.