Evidence map›Paper›PMID 34290900›Full record

ArticleIEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation2016

Dynamic Modeling of Cable Driven Elongated Surgical Instruments for Sensorless Grip Force Estimation.

Yangming Li, Muneaki Miyasaka, Mohammad Haghighipanah, Lei Cheng, Blake Hannaford

Abstract read
In one paragraph

Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Review
  3. Transfer of learned dynamics between different surgical robots and operative configurations.International journal of computer assisted radiology and surgery · 2022
    Article
  4. Pneumatically driven surgical forceps displaying a magnified grasping torque.The international journal of medical robotics + computer assisted surgery : MRCAS · 2020
    Article
  5. Conditions for reliable grip force and jaw angle estimation of da Vinci surgical tools.International journal of computer assisted radiology and surgery · 2019
    Article
  6. Article
  7. Article
  8. Article
  9. Dynamic Modeling of Cable Driven Elongated Surgical Instruments for Sensorless Grip Force Estimation.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yangming LiDepartment of Electrical Engineering, University of Washington, Seattle, WA, USA 98195.
Muneaki MiyasakaDepartment of Mechanical Engineering, University of Washington, Seattle, WA, USA 98195.
Mohammad HaghighipanahDepartment of Electrical Engineering, University of Washington, Seattle, WA, USA 98195.
Lei ChengDepartment of Mechanical Engineering, University of Washington, Seattle, WA, USA 98195.
Blake HannafordDepartments of Electrical Engineering, Bioengineering, Mechanical Engineering, and Surgery, University of Washington, Seattle, WA, USA 98195.

Funding

Computer Modeled Multiportal Approaches to the Skull BaseR21EB016122 · NIBIB · UNIVERSITY OF WASHINGTON · PI HANNAFORD, BLAKE, MOE, KRIS · 2013 to 2014
$386k
NIBIB NIH HHS R21 EB016122
6 · The paper itself

Abstract

Haptic feedback plays a key role in surgeries, but it is still a missing component in robotic Minimally Invasive Surgeries. This paper proposes a dynamic model-based sensorless grip force estimation method to address the haptic perception problem for commonly used elongated cable-driven surgical instruments. Cable and cable-pulley properties are studied for dynamic modeling; grip forces, along with driven motor and gripper jaw positions and velocities are jointly estimated with Unscented Kalman Filter and only motor encoder readings and motor output torques are assumed to be known. A bounding filter is used to compensate for model inaccuracy and to improve method robustness. The proposed method was validated on a 10mm gripper which is driven by a Raven-II surgical robot. The gripper was equipped with 1-dimensional force sensors which served as ground truth data. The experimental results showed that the proposed method provides sufficiently good grip force estimation, while only motor encoder and the motor torques are used as observations.

Indexed as

Dynamic ModelingElongated Cable Driven InstrumentMinimally Invasive SurgerySensorless Grasp Force EstimationSurgical RobotUnscented Kalman Filter

Identifiers

PMID34290900
PMCPMC8291034

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.