Evidence map›Paper›PMID 34290470›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2019

3D-2D Image Registration in Virtual Long-Film Imaging: Application to Spinal Deformity Correction.

A Uneri, X Zhang, J W Stayman, P A Helm, G M Osgood, N Theodore, J H Siewerdsen

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 59% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

A UneriDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
X ZhangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
J W StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
P A HelmMedtronic Inc., Littleton MA.
G M OsgoodDepartment of Orthopaedic Surgery, Johns Hopkins Medicine, Baltimore MD.
N TheodoreDepartment of Neurosurgery, Johns Hopkins Medicine, Baltimore MD.
J H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
Johns Hopkins University · USJohns Hopkins Medicine · USJohns Hopkins Hospital · USMedtronic (United States) · US

Funding

Intraoperative Imaging for Guidance, Patient Safety, and OR Quality AssuranceR01EB017226 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SIEWERDSEN, JEFFREY H · 2014 to 2017
$2.1M
Training In Orthopaedic Team ScienceT32AR067708 · NIAMS · JOHNS HOPKINS UNIVERSITY · PI JONES, LYNNE C., SHAFIQ, BABAR · 2015 to 2024
$2.0M
NIAMS NIH HHS T32 AR067708NIBIB NIH HHS R01 EB017226
6 · The paper itself

Abstract

purposeIntraoperative 2D virtual long-film (VLF) imaging is investigated for 3D guidance and confirmation of the surgical product in spinal deformity correction. Multi-slot-scan geometry (rather than a single-slot "topogram") is exploited to produce parallax views of the scene for accurate 3D colocalization from a single radiograph.

methodsThe multi-slot approach uses additional angled collimator apertures to form fan-beams with disparate views (parallax) of anatomy and instrumentation and to extend field-of-view beyond the linear motion limits. Combined with a knowledge of surgical implants (pedicle screws and/or spinal rods modeled as "known components"), 3D-2D image registration is used to solve for pose estimates via optimization of image gradient correlation. Experiments were conducted in cadaver studies emulating the system geometry of the O-arm (Medtronic, Minneapolis MN).

resultsExperiments demonstrated feasibility of multi-slot VLF and quantified the geometric accuracy of 3D-2D registration using VLF acquisitions. Registration of pedicle screws from a single VLF yielded mean target registration error of (2.0±0.7) mm, comparable to the accuracy of surgical trackers and registration using multiple radiographs (e.g., AP and LAT).

conclusions3D-2D registration in a single VLF image offers a promising new solution for image guidance in spinal deformity correction. The ability to accurately resolve pose from a single view absolves workflow challenges of multiple-view registration and suggests application beyond spine surgery, such as reduction of long-bone fractures.

Indexed as

3D-2D image registrationimage-guided surgeryIntraoperative imaginglinear slot-scanning radiography

Identifiers

PMID34290470
PMCPMC8292105
OpenAlexW2920794267

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.