Evidence map›Paper›PMID 34287303›Full record

ArticleJournal of functional morphology and kinesiology2021

Accuracy of Measuring Knee Flexion after TKA through Wearable IMU Sensors.

Ricardo Antunes, Paul Jacob, Andrew Meyer, Michael A Conditt, Martin W Roche, Matthias A Verstraete

Open access · goldAbstract read
In one paragraph

Article in Journal of functional morphology and kinesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 22 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Ricardo AntunesEnMovi Ltd., Unit 1I, Inovo Building, 121 George St., Glasgow G1 1RD, UK.
Paul JacobOklahoma Joint Reconstruction Institute, 9800 Broadway Ext., Suite 201, Oklahoma City, OK 73114, USA.
Andrew MeyerOrthoSensor Inc., Suite A-310, 1855 Griffin Rd., Dania Beach, FL 33004, USA.
Michael A CondittOrthoSensor Inc., Suite A-310, 1855 Griffin Rd., Dania Beach, FL 33004, USA.ORCID 0000-0002-5966-4667
Martin W RocheOrthoSensor Inc., Suite A-310, 1855 Griffin Rd., Dania Beach, FL 33004, USA.
Matthias A VerstraeteEnMovi Ltd., Unit 1I, Inovo Building, 121 George St., Glasgow G1 1RD, UK.
OrthoSensor (United States) · USHoly Cross Hospital · USOklahoma Blood Institute · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable sensors have the potential to facilitate remote monitoring for patients recovering from knee replacement surgery. Using IMU sensors attached to the patients' leg, knee flexion can be monitored while the patients are recovering in their home environment. Ideally, these flexion angle measurements will have an accuracy and repeatability at least on par with current clinical standards. To validate the clinical accuracy of a two-sensor IMU system, knee flexion angles were measured in eight subjects post-TKA and compared with other in-clinic angle measurement techniques. These sensors are aligned to the patients' anatomy by taking a pose resting their operated leg on a box; an initial goniometer measurement defines the patients' knee flexion while taking that pose. The repeatability and accuracy of the system was subsequently evaluated by comparing knee flexion angles against goniometer readings and markerless optical motion capture data. The alignment pose was repeatable with a mean absolute error of 1.6 degrees. The sensor accuracy through the range of motion had a mean absolute error of 2.6 degrees. In conclusion, the presented sensor system facilitates a repeatable and accurate measurement of the knee flexion, holding the potential for effective remote monitoring of patients recovering from knee replacement surgery.

Indexed as

accuracyflexion measurementsIMU sensorsknee arthroplastywearable sensors

Identifiers

PMID34287303
PMCPMC8293382
OpenAlexW3178695412

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked