Zero-Heat-Flux and Esophageal Temperature Monitoring in Orthopedic Surgery: An Observational Study.

Judy Munday, Niall Higgins, Lee Jones, Dimitrios Vagenas, André Van Zundert, Samantha Keogh

Open access · goldAbstract read
In one paragraph

Article in Journal of multidisciplinary healthcare, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Observational
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Judy MundaySchool of Nursing & Centre for Healthcare Transformation, Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia.ORCID 0000-0003-3596-5235
Niall HigginsSchool of Nursing & Centre for Healthcare Transformation, Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia.ORCID 0000-0002-3260-1711
Lee JonesSchool of Nursing & Centre for Healthcare Transformation, Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia.
Dimitrios VagenasResearch Methods Group, Institute of Health and Biomedical Innovation (IHBI), Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia.
André Van ZundertSchool of Nursing & Centre for Healthcare Transformation, Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia.ORCID 0000-0002-1836-6831
Samantha KeoghSchool of Nursing & Centre for Healthcare Transformation, Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia.
Queensland University of Technology · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePerioperative hypothermia prevention requires regular, accurate, and consistent temperature monitoring. Zero-heat-flux (ZHF) thermometry offers a non-invasive, measurement method that can be applied across all surgical phases. The purpose of this study was to measure agreement between the zero-heat-flux device and esophageal monitoring, sensitivity, and specificity to detect hypothermia and patient acceptability amongst patients undergoing upper and lower limb orthopedic surgery. PATIENTS AND

methodsThis prospective, observational study utilized Bland-Altman analysis and Lin's concordance coefficient to measure agreement between devices, sensitivity and specificity to detect hypothermia and assessed patient acceptability amongst 30 patients between December 2018 and June 2019.

resultsBias was observed between devices via Bland Altman, with bias dependent on actual temperature. The mean difference ranged from -0.16°C at 34.9°C (where the mean of ZHF was lower than the esophageal device) to 0.46°C at 37.25°C (where the mean of ZHF was higher than esophageal device), with 95% limits of agreement (max) upper LOA = 0.80 to 1.41, lower LOA = -1.12 to -0.50. Seventy-five percentage of zero-heat-flux measurements were within 0.5°C of esophageal readings. Patient acceptability was high; 96% (n=27) stated that the device was comfortable.

conclusionZHF device achieved lesser measurement accuracy with core (esophageal) temperature compared to earlier findings. Nonetheless, due to continuous capability, non-invasiveness and patient reported acceptability, the device warrants further evaluation. TITLE REGISTRATION: The study was registered at www.ANZCTR.org.au (reference: ACTRN12619000842167).

Indexed as

perioperativesensitivityspecificitythermometrythermoregulation

Identifiers

PMID34285500
PMCPMC8286425
OpenAlexW3180348016

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.