Evidence map›Paper›PMID 34283101›Full record

ArticleSensors (Basel, Switzerland)2021

Multi-Floor Indoor Pedestrian Dead Reckoning with a Backtracking Particle Filter and Viterbi-Based Floor Number Detection.

Cedric De Cock, Wout Joseph, Luc Martens, Jens Trogh, David Plets

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. A Hybrid Indoor Altimetry Based on Barometer and UWB.Sensors (Basel, Switzerland) · 2023
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Cedric De CockDepartment of Information Technology, IMEC-WAVES/Ghent University, Technologiepark-Zwijnaarde 126, 9052 Gent, Belgium.ORCID 0000-0002-2724-6989
Wout JosephDepartment of Information Technology, IMEC-WAVES/Ghent University, Technologiepark-Zwijnaarde 126, 9052 Gent, Belgium.ORCID 0000-0002-8807-0673
Luc MartensDepartment of Information Technology, IMEC-WAVES/Ghent University, Technologiepark-Zwijnaarde 126, 9052 Gent, Belgium.ORCID 0000-0001-9948-9157
Jens TroghDepartment of Information Technology, IMEC-WAVES/Ghent University, Technologiepark-Zwijnaarde 126, 9052 Gent, Belgium.ORCID 0000-0003-0185-5409
David PletsDepartment of Information Technology, IMEC-WAVES/Ghent University, Technologiepark-Zwijnaarde 126, 9052 Gent, Belgium.ORCID 0000-0002-8879-5076
Ghent University · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We present a smartphone-based indoor localisation system, able to track pedestrians over multiple floors. The system uses Pedestrian Dead Reckoning (PDR), which exploits data from the smartphone's inertial measurement unit to estimate the trajectory. The PDR output is matched to a scaled floor plan and fused with model-based WiFi received signal strength fingerprinting by a Backtracking Particle Filter (BPF). We proposed a new Viterbi-based floor detection algorithm, which fuses data from the smartphone's accelerometer, barometer and WiFi RSS measurements to detect stairs and elevator usage and to estimate the correct floor number. We also proposed a clustering algorithm on top of the BPF to solve multimodality, a known problem with particle filters. The proposed system relies on only a few pre-existing access points, whereas most systems assume or require the presence of a dedicated localisation infrastructure. In most public buildings and offices, access points are often available at smaller densities than used for localisation. Our system was extensively tested in a real office environment with seven 41 m × 27 m floors, each of which had two WiFi access points. Our system was evaluated in real-time and batch mode, since the system was able to correct past states. The clustering algorithm reduced the median position error by 17% in real-time and 13% in batch mode, while the floor detection algorithm achieved a 99.1% and 99.7% floor number accuracy in real-time and batch mode, respectively.

Indexed as

PedestriansAlgorithmsElevators and EscalatorsHumansSmartphoneWalkingbarometerDBSCANfloor transitioningindoor localisationinertial measurement unitparticle filterpedestrian dead reckoningsmartphoneViterbiWiFi

Identifiers

PMID34283101
PMCPMC8271586
OpenAlexW3179988943

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.