Evidence map›Paper›PMID 34282555›Full record

ArticleJournal of robotic surgery2022

Colorectal cancer surgery: by Cambridge Medical Robotics Versius Surgical Robot System-a single-institution study. Our experience.

Shailesh P Puntambekar, K N Rajesh, Arjun Goel, Mangesh Hivre, Suyog Bharambe, Mihir Chitale, Mangesh Panse

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 4 pooled it
1.6field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 4 syntheses or guidelines pooled it, 30 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Da VinciSurgical endoscopy · 2026
    Observational
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Shailesh P Puntambekar, 1-6, Galaxy Care Laparoscopic Institute, Pune, India.
K N Rajesh, 1-6, Galaxy Care Laparoscopic Institute, Pune, India. drrajeshkn1@gmail.com.
Arjun Goel, 1-6, Galaxy Care Laparoscopic Institute, Pune, India.
Mangesh Hivre, 1-6, Galaxy Care Laparoscopic Institute, Pune, India.
Suyog Bharambe, 1-6, Galaxy Care Laparoscopic Institute, Pune, India.
Mihir Chitale, 1-6, Galaxy Care Laparoscopic Institute, Pune, India.
Mangesh Panse, 1-6, Galaxy Care Laparoscopic Institute, Pune, India.
Galaxy Biotech (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the previous experiences in performing laparoscopic for over a period of 15 years and da Vinci colorectal surgeries from 2010 to 2013, we started operating using the Cambridge Medical Robotics (CMR) Versius Surgical Robot System. The aim of the study is a prospective analysis and evaluation of short-term results of consecutive patients to study the technical feasibility and oncological outcome of robot-assisted low anterior resection (LAR) and ultralow anterior resection (ULAR), using the CMR Versius Surgical Robot System. This study was conducted at single minimal access surgery institute. 31 patients with colorectal adenocarcinoma underwent robot-assisted LAR and ULAR between August 2019 and March 2020. Patient characteristics, perioperative parameters and complications were evaluated. Surgical and pathological outcomes such as quality of Total Mesorectal Excision (TME), free circumferential resection margins and number of lymph nodes dissected were also evaluated. Of 31 patients, 23 were men and 8 women, with mean age of 55.6 years. The mean robotic operative time was 51 min and the mean blood loss was 55 ml. The mean robot docking and undocking time was 17 min and 5 min, respectively. The mean hospital stay was 7 days. The longitudinal and circumferential resection margins were negative in all patients. Histopathological reports of 27 among 31 patients showed complete TME. Splenic flexure of colon mobilization was done laparoscopically. We feel that Versius robot has the qualities in terms of dexterity, vision and intuitive movements, and to translate this technical ability into oncological safety.

Indexed as

Digestive System Surgical ProceduresLaparoscopyRectal NeoplasmsRoboticsRobotic Surgical ProceduresFemaleHumansMaleMargins of ExcisionMiddle AgedTreatment OutcomeCMR Versius Surgical Robot SystemLow and ultralow anterior resectionRectal cancerTotal mesorectal excision

Identifiers

PMID34282555
OpenAlexW3186084112

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.