Evidence map›Paper›PMID 34279329›Full record

ArticleMaterials (Basel, Switzerland)2021

A New Setup for Simulating the Corrosion Behavior of Orthodontic Wires.

Polydefkis Papaioannou, Mona Sütel, Katrin Hüsker, Wolf-Dieter Müller, Theodosia Bartzela

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Polydefkis PapaioannouDepartment of Orthodontics, Dentofacial Orthopedics, and Pedodontics, Charité Center for Oral Health Sciences, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of Health, Assmannshauser Str. 4-6, 19147 Berlin, Germany.
Mona SütelDepartment of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Center for Oral Health Sciences, Dental Materials and Biomaterial Research, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of HealthAßmannshauser Str. 4-6, 14197 Berlin, Germany.
Katrin HüskerDepartment of Immunology, IMD Institute of Medical Diagnostics Berlin-Potsdam GbR, 12247 Berlin, Germany.
Wolf-Dieter MüllerDepartment of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Center for Oral Health Sciences, Dental Materials and Biomaterial Research, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of HealthAßmannshauser Str. 4-6, 14197 Berlin, Germany.
Theodosia BartzelaDepartment of Orthodontics, Dentofacial Orthopedics, and Pedodontics, Charité Center for Oral Health Sciences, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of Health, Assmannshauser Str. 4-6, 19147 Berlin, Germany.ORCID 0000-0001-8478-2078
Humboldt-Universität zu Berlin · DEInstitut für Medizinische Diagnostik Berlin-Potsdam · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to create a new reliable setup to evaluate commercially available orthodontic wires used during orthodontic treatment. The setup includes various techniques applied for testing metal alloy materials. The materials were tested under extreme conditions to simulate their behavior in the mouth. The alloy composition of each wire was tested. The electrochemical (EC) testing and characterization of the corrosion performance of the wires was calculated by the electrochemical curves at pH = 1 in two different applied potentials to test the reaction of the material. The liquid collected after the EC measurements was analyzed by inductively coupled plasma-mass spectrometry (ICP-MS) to verify the reliability of the EC curves and for a more accurate evaluation of the corrosion behavior of the wires. Therefore, the EC measurements were compared to the actual values obtained from the released ions found in the solution. At the end, a surface analysis was performed to detect corrosion on the wires. In conclusion, this study developed a setup to test and better understand the corrosion behavior and ion release of the orthodontic wires, metal alloy dental materials, and other metals used in the oral cavity. This method can contribute to dental material selection in patients with underlying health conditions.

Indexed as

corrosionelectrochemical testICP-MS analysisMini Cell Systemorthodontic wires

Identifiers

PMID34279329
PMCPMC8269849
OpenAlexW3178896386

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.