ArticleApplied soft computing2021
Correcting data imbalance for semi-supervised COVID-19 detection using X-ray chest images.
Article in Applied soft computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Challenges issues and future recommendations of deep learning techniques for SARS-CoV-2 detection utilising X-ray and CT images: a comprehensive review.PeerJ. Computer science · 2024Article
- Detection of Covid-19 and other pneumonia cases from CT and X-ray chest images using deep learning based on feature reuse residual block and depthwise dilated convolutions neural network.Applied soft computing · 2023Article
- Dealing with distribution mismatch in semi-supervised deep learning for COVID-19 detection using chest X-ray images: A novel approach using feature densities.Applied soft computing · 2022Article
- A real use case of semi-supervised learning for mammogram classification in a local clinic of Costa Rica.Medical & biological engineering & computing · 2022Article
- Lung Disease Classification in CXR Images Using Hybrid Inception-ResNet-v2 Model and Edge Computing.Journal of healthcare engineering · 2022Article
- CCT: Lightweight compact convolutional transformer for lung disease CT image classification.Frontiers in physiology · 2022Article
- CovidXrayNet: Optimizing data augmentation and CNN hyperparameters for improved COVID-19 detection from CXR.Computers in biology and medicine · 2021Article
- Improving Uncertainty Estimation With Semi-Supervised Deep Learning for COVID-19 Detection Using Chest X-Ray Images.IEEE access : practical innovations, open solutions · 2021Article
- Explainable Machine Learning for COVID-19 Pneumonia Classification With Texture-Based Features Extraction in Chest Radiography.Frontiers in digital health · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A key factor in the fight against viral diseases such as the coronavirus (COVID-19) is the identification of virus carriers as early and quickly as possible, in a cheap and efficient manner. The application of deep learning for image classification of chest X-ray images of COVID-19 patients could become a useful pre-diagnostic detection methodology. However, deep learning architectures require large labelled datasets. This is often a limitation when the subject of research is relatively new as in the case of the virus outbreak, where dealing with small labelled datasets is a challenge. Moreover, in such context, the datasets are also highly imbalanced, with few observations from positive cases of the new disease. In this work we evaluate the performance of the semi-supervised deep learning architecture known as MixMatch with a very limited number of labelled observations and highly imbalanced labelled datasets. We demonstrate the critical impact of data imbalance to the model's accuracy. Therefore, we propose a simple approach for correcting data imbalance, by re-weighting each observation in the loss function, giving a higher weight to the observations corresponding to the under-represented class. For unlabelled observations, we use the pseudo and augmented labels calculated by MixMatch to choose the appropriate weight. The proposed method improved classification accuracy by up to 18%, with respect to the non balanced MixMatch algorithm. We tested our proposed approach with several available datasets using 10, 15 and 20 labelled observations, for binary classification (COVID-19 positive and normal cases). For multi-class classification (COVID-19 positive, pneumonia and normal cases), we tested 30, 50, 70 and 90 labelled observations. Additionally, a new dataset is included among the tested datasets, composed of chest X-ray images of Costa Rican adult patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.