Evidence map›Paper›PMID 34272890›Full record

ArticleMedical physics2021

High-resolution model-based material decomposition in dual-layer flat-panel CBCT.

Wenying Wang, Yiqun Ma, Matthew Tivnan, Junyuan Li, Grace J Gang, Wojciech Zbijewski, Minghui Lu, Jin Zhang, Josh Star-Lack, Richard E Colbeth and 1 more

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. One-Step Material Decomposition Using Spectral Diffusion Posterior Sampling in Sparse-View Dual-Layer CT.Proceedings of SPIE--the International Society for Optical Engineering · 2026
    Article
  2. Article
  3. Multi-Material Decomposition Using Spectral Diffusion Posterior Sampling.IEEE transactions on bio-medical engineering · 2025
    Article
  4. Article
  5. CT Material Decomposition using Spectral Diffusion Posterior Sampling.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2024
    Article
  6. Spectral Orbits: Combining Spectral Imaging and Non-Circular Orbits for Interventional CBCT.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2024
    Article
  7. Article
  8. Article
  9. Evaluation of a Large Area, 83IEEE transactions on electron devices · 2024
    Article
  10. Article
  11. Three-material decomposition using a dual-layer flat panel detector in the presence of soft tissue motion.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  12. Approaches for Three Material Decomposition using a Triple-Layer Flat-Panel Detector.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Wenying WangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.
Yiqun MaDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.
Matthew TivnanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.
Junyuan LiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.
Grace J GangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.
Wojciech ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.
Minghui LuVarex Imaging Corp., 683 River Oaks Pkwy, San Jose, CA, 95134, USA.
Jin ZhangVarex Imaging Corp., 683 River Oaks Pkwy, San Jose, CA, 95134, USA.
Josh Star-LackVarex Imaging Corp., 683 River Oaks Pkwy, San Jose, CA, 95134, USA.
Richard E ColbethVarex Imaging Corp., 683 River Oaks Pkwy, San Jose, CA, 95134, USA.
J Webster StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.

Funding

Monitoring of fractures with internal fixators using weight-bearing quantitative cone beam CTR01EB025470 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER, ZBIJEWSKI, WOJCIECH BARTOSZ · 2018 to 2021
$1.5M
Spectral-spatial filtering for efficient multi-material decomposition in x-ray CTR21EB026849 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2018 to 2019
$450k
NIBIB NIH HHS R01 EB025470NIBIB NIH HHS R21 EB026849
6 · The paper itself

Abstract

purposeSpectral CT uses energy-dependent measurements that enable material discrimination in addition to reconstruction of structural information. Flat-panel detectors (FPDs) have been widely used in dedicated and interventional systems to deliver high spatial resolution, volumetric cone-beam CT (CBCT) in compact and OR-friendly designs. In this work, we derive a model-based method that facilitates high-resolution material decomposition in a spectral CBCT system equipped with a prototype dual-layer FPD. Through high-fidelity modeling of multilayer detector, we seek to avoid resolution loss that is present in more traditional processing and decomposition approaches.

methodA physical model for spectral measurements in dual-layer flat-panel CBCT is developed including layer-dependent differences in system geometry, spectral sensitivities, and detector blur (e.g., due to varied scintillator thicknesses). This forward model is integrated into a model-based material decomposition (MBMD) method based on minimization of a penalized weighted least-squared (PWLS) objective function. The noise and resolution performance of this approach was compared with traditional projection-domain decomposition (PDD) and image-domain decomposition (IDD) approaches as well as one-step MBMD with lower-fidelity models that use approximated geometry, projection interpolation, or an idealized system geometry without system blur model. Physical studies using high-resolution three-dimensional (3D)-printed water-iodine phantoms were conducted to demonstrate the high-resolution imaging performance of the compared decomposition methods in iodine basis images and synthetic monoenergetic images.

resultsPhysical experiments demonstrate that the MBMD methods incorporating an accurate geometry model can yield higher spatial resolution iodine basis images and synthetic monoenergetic images than PDD and IDD results at the same noise level. MBMD with blur modeling can further improve the spatial-resolution compared with the decomposition results obtained with IDD, PDD, and MBMD methods with lower-fidelity models. Using the MBMD without or with blur model can increase the absolute modulation at 1.75 lp/mm by 10% and 22% compared with IDD at the same noise level.

conclusionThe proposed model-based material decomposition method for a dual-layer flat-panel CBCT system has demonstrated an ability to extend high-resolution performance through sophisticated detector modeling including the layer-dependent blur. The proposed work has the potential to not only facilitate high-resolution spectral CT in interventional and dedicated CBCT systems, but may also provide the opportunity to evaluate different flat-panel design trade-offs including multilayer FPDs with mismatched geometries, scintillator thicknesses, and spectral sensitivities.

Indexed as

Spiral Cone-Beam Computed TomographyCone-Beam Computed TomographyLeast-Squares AnalysisModels, TheoreticalPhantoms, Imagingdual-layer detectormaterial decompositionmodel-based iterative reconstructionspectral CT

Identifiers

PMID34272890
PMCPMC10792526

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.