Evidence map›Paper›PMID 34272469›Full record

SynthesisJournal of perinatology : official journal of the California Perinatal Association2021

Adverse events associated with umbilical catheters: a systematic review and meta-analysis.

Kim Gibson, Rebecca Sharp, Amanda Ullman, Scott Morris, Tricia Kleidon, Adrian Esterman

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Journal of perinatology : official journal of the California Perinatal Association, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Real-time ultrasound to assess the umbilical catheter position in neonates: a randomized, controlled trial.Journal of perinatology : official journal of the California Perinatal Association · 2025
    Trial
  2. Article
  3. Vascular device practices in extremely preterm infants: an international cross-sectional survey.Journal of perinatology : official journal of the California Perinatal Association · 2026
    Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Group BAJP reports · 2026
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Reducing umbilical catheter migration rates by using a novel securement device.Journal of perinatology : official journal of the California Perinatal Association · 2024
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kim GibsonClinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia. Kim.gibson@unisa.edu.au.ORCID http://orcid.org/0000-0002-4174-5653
Rebecca SharpClinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia.
Amanda UllmanChildren's Health Queensland and Health Service, Centre of Children's Health Research, South Brisbane, QLD, Australia.
Scott MorrisNeonatal Unit, Flinders Medical Centre, Bedford Park, SA, Australia.
Tricia KleidonQueensland Children's Hospital, South Brisbane, QLD, Australia.
Adrian EstermanClinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo determine the incidence of adverse events (AEs) associated with umbilical catheters in the neonatal population. STUDY

designSystematic review and meta-analysis of observational studies and randomized controlled trials published between 2010 and 2020.

resultsIn total 14,226 umbilical venous catheters (UVCs) and 4228 umbilical arterial catheters (UACs) were included. Overall, 13.4% of UVCs were associated with an AE (95% CI: 10.1-17.0) or 2.4 per 1000 catheter days (95% CI: 1.8-3.0). UACs had an AE rate of 9% (95% CI: 5.9-12.8) or 0.87 per 1000 catheter days (95% CI: 0.4-1.3). UVC malposition was the most common (41.7% [95% CI: 27.6-56.5]). Local injury from UAC taping was the most common AE in one study.

conclusionsUmbilical catheters have a high incidence of AEs. Research into accurate methods of tip verification, tip surveillance, and securement is required.

Indexed as

Catheterization, PeripheralVascular Access DevicesCathetersCatheters, IndwellingHumansInfant, NewbornUmbilical VeinsUmbilicus

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.