Evidence map›Paper›PMID 34272408›Full record

ArticleScientific reports2021

3D printed microfluidic lab-on-a-chip device for fiber-based dual beam optical manipulation.

Haoran Wang, Anton Enders, John-Alexander Preuss, Janina Bahnemann, Alexander Heisterkamp, Maria Leilani Torres-Mapa

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 43 citations in OpenAlex.

  1. Article
  2. 3D Hybrid Bioprinting for Complex Multi-Tissue Engineering.bioRxiv : the preprint server for biology · 2025
    Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Article
  12. Review
  13. Optimization of 3D printing andFrontiers in bioengineering and biotechnology · 2023
    Article
  14. Review
  15. Article
  16. Recent progress of microfluidic chips in immunoassay.Frontiers in bioengineering and biotechnology · 2022
    Review
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Haoran WangInstitute of Quantum Optics, Gottfried Wilhelm Leibniz University Hannover, Welfengarten 1, 30167, Hannover, Germany.
Anton EndersInstitute of Technical Chemistry, Gottfried Wilhelm Leibniz University Hannover, Callinstrasse 5, 30167, Hannover, Germany.
John-Alexander PreussInstitute of Technical Chemistry, Gottfried Wilhelm Leibniz University Hannover, Callinstrasse 5, 30167, Hannover, Germany.
Janina BahnemannInstitute of Technical Chemistry, Gottfried Wilhelm Leibniz University Hannover, Callinstrasse 5, 30167, Hannover, Germany.
Alexander HeisterkampInstitute of Quantum Optics, Gottfried Wilhelm Leibniz University Hannover, Welfengarten 1, 30167, Hannover, Germany.
Maria Leilani Torres-MapaInstitute of Quantum Optics, Gottfried Wilhelm Leibniz University Hannover, Welfengarten 1, 30167, Hannover, Germany. torres@iqo.uni-hannover.de.
Leibniz University Hannover · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

3D printing of microfluidic lab-on-a-chip devices enables rapid prototyping of robust and complex structures. In this work, we designed and fabricated a 3D printed lab-on-a-chip device for fiber-based dual beam optical manipulation. The final 3D printed chip offers three key features, such as (1) an optimized fiber channel design for precise alignment of optical fibers, (2) an optically clear window to visualize the trapping region, and (3) a sample channel which facilitates hydrodynamic focusing of samples. A square zig-zag structure incorporated in the sample channel increases the number of particles at the trapping site and focuses the cells and particles during experiments when operating the chip at low Reynolds number. To evaluate the performance of the device for optical manipulation, we implemented on-chip, fiber-based optical trapping of different-sized microscopic particles and performed trap stiffness measurements. In addition, optical stretching of MCF-7 cells was successfully accomplished for the purpose of studying the effects of a cytochalasin metabolite, pyrichalasin H, on cell elasticity. We observed distinct changes in the deformability of single cells treated with pyrichalasin H compared to untreated cells. These results demonstrate that 3D printed microfluidic lab-on-a-chip devices offer a cost-effective and customizable platform for applications in optical manipulation.

Identifiers

PMID34272408
PMCPMC8285473
OpenAlexW3182051420

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked