MRI with sub-millisecond temporal resolution over a reduced field of view.

Zheng Zhong, Kaibao Sun, Guangyu Dan, Qingfei Luo, Xiaohong Joe Zhou

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Zheng ZhongCenter for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.ORCID 0000-0002-0162-5964
Kaibao SunCenter for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.ORCID 0000-0001-6923-5914
Guangyu DanCenter for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.ORCID 0000-0003-0427-5661
Qingfei LuoCenter for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.ORCID 0000-0001-5574-817X
Xiaohong Joe ZhouCenter for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.ORCID 0000-0003-0793-4925
University of Illinois Chicago · US

Funding

A High-End 3 Tesla Human MRI Scanner Dedicated to ResearchS10RR028898 · NCRR · UNIVERSITY OF ILLINOIS AT CHICAGO · PI ZHOU, XIAOHONG JOE · 2010 to 2010
$2.9M
Probing Intra-voxel Tissue Heterogeneity Using MRIR01EB026716 · NIBIB · UNIVERSITY OF ILLINOIS AT CHICAGO · PI ZHOU, XIAOHONG JOE · 2018 to 2022
$1.7M
NCRR NIH HHS S10 RR028898NIBIB NIH HHS R01 EB026716
6 · The paper itself

Abstract

purposeTo demonstrate an MRI pulse sequence-Sub-millisecond Periodic Event Encoded Dynamic Imaging with a reduced field of view (or rFOV-SPEEDI)-for decreasing the scan times while achieving sub-millisecond temporal resolution.

methodsrFOV-SPEEDI was based on a variation of SPEEDI, known as get-SPEEDI, which used each echo in an echo-train to sample a distinct k-space raster by synchronizing with a cyclic event. This can produce a set of time-resolved images of the cyclic event with a temporal resolution determined by the echo spacing (typically < 1 ms). rFOV-SPEEDI incorporated a 2D radiofrequency (RF) pulse into get-SPEEDI to limit the field of view (FOV), leading to reduction in phase-encoding steps and subsequently decreased scan times without compromising the spatial resolution. Two experiments were performed at 3T to illustrate rFOV-SPEEDI's capability of capturing fast-changing electric currents in a phantom and the rapid opening and closing of aortic valve in human subjects over reduced FOVs. The results were compared with those from full FOV get-SPEEDI.

resultsIn the first experiment, the rapidly varying currents (50-200 Hz) were successfully captured with a temporal resolution of 0.8 ms, and agreed well with the applied currents. In the second experiment, the rapid opening and closing processes of aortic valve were clearly visualized with a temporal resolution of 0.6 ms over a reduced FOV (12 × 12 cm

conclusionReducing the FOV is a viable approach to shortening the scan times in SPEEDI, which is expected to help stimulate SPEEDI applications for studying ultrafast, cyclic physiological and biophysical processes over a focal region.

Indexed as

Aortic ValveMagnetic Resonance ImagingHumansPhantoms, ImagingRadio Wavesaortic valvereduced field-of-viewsub-millisecondtemporal resolutionultrafast imaging

Identifiers

PMID34270138
PMCPMC8568630
OpenAlexW3177550863

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.