A T1-based correction method for proton resonance frequency shift thermometry in breast tissue.

McKenzie McLean, Dennis L Parker, Henrik Odéen, Allison Payne

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

McKenzie McLeanUniversity of Utah, Salt Lake City, UT, USA.
Dennis L ParkerUniversity of Utah, Salt Lake City, UT, USA.
Henrik OdéenUniversity of Utah, Salt Lake City, UT, USA.
Allison PayneUniversity of Utah, Salt Lake City, UT, USA.

Funding

Validation and translation of a non-invasive, MR-guided breast cancer therapyR37CA224141 · NCI · UNIVERSITY OF UTAH · PI PAYNE, ALLISON · 2018 to 2024
$3.7M
Toward the next generation in transcranial MR-guided focused ultrasound: Innovations in thermal and acoustic model-based planning and monitoring for improved safety, efficacy and efficiencyR01EB028316 · NIBIB · UNIVERSITY OF UTAH · PI PARKER, DENNIS L, RIEKE, VIOLA · 2019 to 2022
$2.5M
Siemens MAGNETOM Prisma 3T MRI scannerS10OD018482 · OD · UNIVERSITY OF UTAH · PI PARKER, DENNIS L · 2015 to 2015
$1.2M
Advanced Treatment Endpoint Assessment in MR-guided Focused UltrasoundR03EB029204 · NIBIB · UNIVERSITY OF UTAH · PI ODEEN, HENRIK CARL AXEL · 2020 to 2021
$153k
NCI NIH HHS R37 CA224141NIBIB NIH HHS R01 EB028316NIBIB NIH HHS R03 EB029204NIH HHS 1R37CA224141NIH HHS R01EB028316NIH HHS S10 OD018482
6 · The paper itself

Abstract

purposeDevelop and evaluate the effectiveness of a T1-based correction method for errors in proton resonant frequency shift thermometry due to non-local field effects caused by heating in fatty breast tissues.

methodsComputational models of human breast tissue were created by segmenting MRI data from a healthy human volunteer. MR-guided focused ultrasound (MRgFUS) heating and MR thermometry measurements were simulated in several locations in the heterogeneous segmented breast models. A T1-based correction method for PRF thermometry errors was applied and the maximum positive and negative errors and the root mean squared error (RMSE) in a region around each heating location was evaluated with and without correction. The method uses T1 measurements to estimate the temperature change in fatty tissues and correct for their influence. Experimental data from a heating study in cadaver breast tissue were analyzed, and the expected PRFS error computed.

resultsThe simulated MR thermometry had maximum single voxel errors ranging between 10% and 18% when no correction was applied. Applying the correction led to a considerable improvement, lowering the maximum error range to 2%-5%. The 5th to 95th percentile interval of the temperature error distribution was also lowered with correction, from approximately 3.5 to 1°C. This correction worked even when T1 times were uniformly raised or lowered by 5%-10%. The experimental data showed predicted errors of 15%.

conclusionsThis simulation study demonstrates that the T1-based correction method reduces MR thermometry errors due to non-local effects from heating in fatty tissues, potentially improving the accuracy of thermometry measurements during MRgFUS treatments. The presented correction method is reliant on having a patient-specific 3D model of the breast, and may be limited by the accuracy of the fat temperatures which in turn may be limited by noise or bias present in the T1 measurements.

Indexed as

ProtonsThermometryBreastHumansMagnetic Resonance ImagingUltrasonographyProtonsmagnetic resonance thermometryPRFT1tumor ablation

Identifiers

PMID34265109
PMCPMC8502529

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.