ArticleArchives of orthopaedic and trauma surgery2021
An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA.
Article in Archives of orthopaedic and trauma surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Switching From a 6° to a 20° Valgus Prosthetic Trochlear Groove Improved the Forgotten Joint and Oxford Knee Scores After Kinematically Aligned Total Knee Arthroplasty.Arthroplasty today · 2026Article
- Valgus knee deserves personalized total knee arthroplasty.EFORT open reviews · 2026Review
- Restoration of the trochlear peaks is unnecessary with a kinematic alignment-optimized femoral component as under-stuffing results in equivalent or better patient-reported outcome scores.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Article
- No Radiographic Evidence of Medial Collateral Ligament Elongation in Valgus Osteoarthritic Knees Enables Treatment with Kinematically Aligned Total Knee Arthroplasty.The journal of knee surgery · 2025Article
- Article
- An Insert Goniometer Can Help Select the Optimal Insert Thickness When Performing Kinematically Aligned Total Knee Arthroplasty with a Medial 1:1 Ball-in-Socket and Lateral Flat Surface Insert and Posterior Cruciate Ligament Retention.Bioengineering (Basel, Switzerland) · 2024Review
- PCL retention demonstrates better functional scores and gait patterns in total knee arthroplasty using a medial congruent insert-a prospective study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- More passive internal tibial rotation with posterior cruciate ligament retention than with excision in a medial pivot TKA implanted with unrestricted caliper verified kinematic alignment.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Measurement of Tibial Orientation Helps Select the Optimal Insert Thickness to Personalize PCL Tension in a Medial Ball-in-Socket TKA.Journal of personalized medicine · 2022Article
- A TKA Insert with A Lateral Flat Articular Surface Maximizes External and Internal Tibial Orientations without Anterior Lift-Off Relative to Low- and Ultracongruent Surfaces.Journal of personalized medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionIn total knee arthroplasty (TKA), the level of conformity, a medial stabilized (MS) implant, needs to restore native (i.e., healthy) knee kinematics without over-tensioning the flexion space when the surgeon chooses to retain the posterior cruciate ligament (PCL) is unknown. Whether an insert with a medial ball-in-socket conformity and lateral flat surface like the native knee or a less than spherical medial conformity restores higher and closer to native internal tibial rotation without anterior lift-off, an over-tension indicator, when implanted with calipered kinematic alignment (KA), is unknown. METHODS AND MATERIALS: Two surgeons treated 21 patients with calipered KA and a PCL retaining MS implant. Validated verification checks that restore native tibial compartment forces in passive flexion without release of healthy ligaments were used to select the optimal insert thickness. A goniometer etched onto trial inserts with the ball-in-socket and the less than spherical medial conformity measured the tibial rotation relative to the femoral component at extension and 90° and 120° flexion. The surgeon recorded the incidence of anterior lift-off of the insert.
resultsThe insert with the medial ball-in-socket and lateral flat surface restored more internal tibial rotation than the one with less than spherical medial conformity, with mean values of 19° vs. 17° from extension to 90° flexion (p < 0.01), and 23° vs. 20°-120° flexion (p < 0.002), respectively. There was no anterior lift-off of the insert at 90° and 120° flexion.
conclusionAn MS insert with a medial ball-in-socket and lateral flat surface that matches the native knee's spherical conformity restores native tibial internal rotation when implanted with calipered KA and PCL retention without over-tensioning the flexion space.