An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA.

Alexander J Nedopil, Adithya Shekhar, Stephen M Howell, Maury L Hull

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alexander J NedopilDepartment of Orthopaedic Surgery, König-Ludwig-Haus, University of Würzburg, Würzburg, Germany. nedopil@me.com.ORCID http://orcid.org/0000-0002-3655-158X
Adithya ShekharCalifornia Northstate University, Elk Grove, USA.
Stephen M HowellDepartment of Biomedical Engineering, University of California, Davis, 451 E. Health Sciences Drive, Room 2303, Davis, CA, 95616, USA.
Maury L HullDepartment of Biomedical Engineering, University of California, Davis, 451 E. Health Sciences Drive, Room 2303, Davis, CA, 95616, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn total knee arthroplasty (TKA), the level of conformity, a medial stabilized (MS) implant, needs to restore native (i.e., healthy) knee kinematics without over-tensioning the flexion space when the surgeon chooses to retain the posterior cruciate ligament (PCL) is unknown. Whether an insert with a medial ball-in-socket conformity and lateral flat surface like the native knee or a less than spherical medial conformity restores higher and closer to native internal tibial rotation without anterior lift-off, an over-tension indicator, when implanted with calipered kinematic alignment (KA), is unknown. METHODS AND MATERIALS: Two surgeons treated 21 patients with calipered KA and a PCL retaining MS implant. Validated verification checks that restore native tibial compartment forces in passive flexion without release of healthy ligaments were used to select the optimal insert thickness. A goniometer etched onto trial inserts with the ball-in-socket and the less than spherical medial conformity measured the tibial rotation relative to the femoral component at extension and 90° and 120° flexion. The surgeon recorded the incidence of anterior lift-off of the insert.

resultsThe insert with the medial ball-in-socket and lateral flat surface restored more internal tibial rotation than the one with less than spherical medial conformity, with mean values of 19° vs. 17° from extension to 90° flexion (p < 0.01), and 23° vs. 20°-120° flexion (p < 0.002), respectively. There was no anterior lift-off of the insert at 90° and 120° flexion.

conclusionAn MS insert with a medial ball-in-socket and lateral flat surface that matches the native knee's spherical conformity restores native tibial internal rotation when implanted with calipered KA and PCL retention without over-tensioning the flexion space.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisBiomechanical PhenomenaHumansKnee JointRange of Motion, ArticularTibiaCaliperedConformingInsertKinematic alignmentMedial stabilizedRotationSphericalTotal knee arthroplastyTotal knee replacement

Identifiers

PMID34264381
PMCPMC8595155

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.