CT Assessment of Intraorbital Cable Movement of Electronic Subretinal Prosthesis in Three Different Surgical Approaches.

Hanna Faber, Ulrike Ernemann, Helmut Sachs, Florian Gekeler, Søren Danz, Assen Koitschev, Dorothea Besch, Karl-Ulrich Bartz-Schmidt, Eberhart Zrenner, Katarina Stingl and 1 more

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 6 institutions in 1 country.

Hanna FaberUniversity Eye Hospital, Center for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
Ulrike ErnemannDepartment of Diagnostic and Interventional Neuroradiology, Radiological Clinic, University of Tuebingen, Tuebingen, Germany.
Helmut SachsOphthalmology Clinic, Städtisches Klinikum Dresden Friedrichstadt, Dresden, Germany.
Florian GekelerOphthalmology Clinic, Klinikum Stuttgart, Stuttgart, Germany.
Søren DanzRadiologische Praxis Hofbauer Danz Fischer, Sindelfingen, Germany.
Assen KoitschevClinic for Ear, Nose and Throat Disorders, Plastic Surgery, Klinikum Stuttgart, Stuttgart, Germany.
Dorothea BeschUniversity Eye Hospital, Center for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
Karl-Ulrich Bartz-SchmidtUniversity Eye Hospital, Center for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
Eberhart ZrennerUniversity Eye Hospital, Center for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
Katarina StinglUniversity Eye Hospital, Center for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
Christoph KernstockUniversity Eye Hospital, Center for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
STZ eyetrial · DEKlinikum Stuttgart · DEFischer (Germany) · DESenckenberg Centre for Human Evolution and Palaeoenvironment · DEStädtisches Klinikum Dresden · DEUniversity of Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Electronic retinal implants restore some visual perception in patients blind from retinitis pigmentosa. Eye movements cause mechanical stress in intraorbital power supply cables leading to cable breaks. By using computer tomography (CT) scans at the extreme positions of the four cardinal gaze directions, this study determined in vivo, which of three surgical routing techniques results in minimal bending radius variation and favors durability. Methods: Nine patients received the first-generation subretinal implant Alpha IMS (Retina Implant AG, Reutlingen, Germany) in one eye. Three techniques for intraorbital cable routing were used (straight cable route (A), parabulbar loop (B), and encircling band (C)), each in three patients. All patients underwent computer tomography of the orbital region. The bending radius of the intraorbital cable was measured with the DICOM viewer Osirix v4.1.2 (Pixmeo SARL, Bernex, Switzerland) and served as indicator for mechanical stress. Results: Average bending radius variation was 87% for method A, 11% for method B, and 16% for method C. Methods A and B (P = 0.005) and methods A and C (P = 0.007) differed significantly, while method B and C showed no statistical difference (P = 0.07). Conclusions: Compared to straight routes, arcuated cable routes significantly reduce cable movement and bending. Due to an easier surgical procedure, a parabulbar loop is the preferred method to minimize bending radius variation and prolong survival time of electronic subretinal implants. Translational Relevance: CT analysis of cable bending of implanted medical devices allows to determine which surgical routing technique favors durability in vivo.

Indexed as

TomographyTomography, X-Ray ComputedComputersElectrodes, ImplantedElectronicsGermanyHumansSwitzerland