ArticlemSphere2021
Optimization and Stability Testing of Four Commercially Available Dried Blood Spot Devices for Estimating Measles and Rubella IgG Antibodies.
Article in mSphere, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 20 citations in OpenAlex.
- Serological survey to determine measles and rubella immunity gaps across age and geographic locations in The Gambia: a study protocol.Global health action · 2025Article
- Standardization of Microsampling Technologies for Accurate Sensing and Reliable Diagnostics.ACS sensors · 2025Review
- Dried Spot Paradigm: Problems and Prospects in Proteomics.International journal of molecular sciences · 2025Review
- Evaluation of SARS-CoV-2 Antibody Response Between Paired Fingerprick (HemaPENAntibodies (Basel, Switzerland) · 2025Article
- Advancements in Mass Spectrometry-Based Targeted Metabolomics and Lipidomics: Implications for Clinical Research.Molecules (Basel, Switzerland) · 2024Review
- RSV Neutralizing Antibodies in Dried Blood.The Journal of infectious diseases · 2024Article
- Exploring Natural Immune Responses toOpen forum infectious diseases · 2024Article
- Electrochemical Immunosensor for the Quantification of Galectin-3 in Saliva.Sensors and actuators. B, Chemical · 2024Article
- Revolutionizing Blood Collection: Innovations, Applications, and the Potential of Microsampling Technologies for Monitoring Metabolites and Lipids.Metabolites · 2024Review
- Pre-analytical conditions influencing analysis of folate in dried plasma microsamples.Journal of mass spectrometry and advances in the clinical lab · 2023Article
- Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2.ACS measurement science au · 2022Article
- Overview of the Analytes Applied in Genotypic HIV Drug Resistance Testing.Pathogens (Basel, Switzerland) · 2022Review
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors at 4 institutions in 2 countries.
Funding
Abstract
Blood collection using dried blood spots (DBS) provides an easier alternative to venipuncture for sample collection, transport, and storage but requires additional processing that can cause variability in results. Whole-blood samples spotted on four DBS devices and respective paired serum samples were tested for antimeasles and antirubella IgG antibody concentrations by enzyme immunoassay. Elution protocols for DBS devices were optimized for comparability relative to serum samples using 12 adult volunteers. Stability of DBS collected on HemaSpot HF was assessed under various temperature conditions (+4, 22 to 25, and 45°C) at six time points (0, 7, 15, 30, 60, and 90 days) in a controlled laboratory setting using six adult volunteers. Devices were shipped and stored for 30 days at four settings with variable temperature and humidity conditions to assess the impact on antibody concentrations. Three DBS devices demonstrated comparable antibody concentrations with paired sera following optimization. Antibodies recovered from DBS were stable for at least 90 days at 4°C and for 30 days at ambient temperature (22 to 25°C) using the HemaSpot HF device. A drastic decline in antibody concentrations was observed at 45°C, resulting in quantitative and qualitative discrepancies by day 7. HemaSpot HF devices shipped to field sites and stored at ambient temperature and humidity resulted in quantitative, but not qualitative, variability. Measurement of antimeasles and antirubella IgG antibodies with DBS devices is an accurate alternative to testing serum, provided elution protocols are optimized. Stability of HemaSpot HF devices at ambient temperature enables broader use in surveys when serum processing and cold storage are not feasible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.