ArticleEndoscopic ultrasound
EUS-guided hepaticoenterostomy with using a dedicated plastic stent for the benign pancreaticobiliary diseases: A single-center study of a large case series.
Article in Endoscopic ultrasound. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 32 citations in OpenAlex.
- Prospective Clinical Evaluation of a Novel Repositionable Plastic Stent for Endosonography-Guided Hepaticogastrostomy With or Without Antegrade Stenting (With Videos).Journal of gastroenterology and hepatology · 2026Article
- International Consensus Statements on Endoscopic Ultrasound-Guided Biliary Drainage: Results From the 1st JGES International in 2025.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026Article
- Inward migration of a dedicated hepaticogastrostomy plastic stent into the bile duct after hepaticojejunostomy.Endoscopy · 2026Article
- Article
- Review
- Troubleshooting: intraperitoneal migration of a dedicated plastic stent during endoscopic ultrasound-guided hepaticogastrostomy.Endoscopy · 2026Article
- Endoscopic ultrasound-guided hepaticogastrostomy using a 22G needle with a 0.018-inch ultra-stiff guidewire without tract dilation.Endoscopy · 2025Article
- The efficacy of 3D hologram support with mixed-reality technique in pancreatobiliary endoscopy.Journal of hepato-biliary-pancreatic sciences · 2025Article
- Metal stent versus plastic stent in endoscopic ultrasound-guided hepaticogastrostomy for unresectable malignant biliary obstruction: Large single-center retrospective comparative study.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2025Article
- A case of successful endoscopic ultrasound/endosonography-guided pancreaticogastrostomy using a novel plastic stent.Endoscopy · 2024Article
- Long-term outcomes of endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction.United European gastroenterology journal · 2024Article
- Is Endoscopic Ultrasound-Guided Hepaticogastrostomy Safe and Effective after Failed Endoscopic Retrograde Cholangiopancreatography?-A Systematic Review and Meta-Analysis.Journal of clinical medicine · 2024Review
- Spontaneous migration of a dedicated plastic stent after endoscopic ultrasound-guided hepaticogastrostomy in a patient with surgically altered anatomy: a case report.Journal of rural medicine : JRM · 2024Article
- Article
- EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla.Endoscopy international open · 2024Article
- Transluminal antegrade drill dilation technique for hepaticojejunostomy stricture with cholangioscopic evaluation (with video).Endoscopy international open · 2024Article
- Biliary and pancreatic stents.iGIE : innovation, investigation and insights · 2023Article
- Loop technique for guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy.JGH open : an open access journal of gastroenterology and hepatology · 2023Article
- Comparison of time to recurrent biliary obstruction between plastic stents and metallic stents for endoscopic ultrasound‑guided biliary drainage.Experimental and therapeutic medicine · 2023Article
- Endoscopic Ultrasound-Guided Hepaticogastrostomy with Antegrade Stenting Without Dilation Device Application for Malignant Distal Biliary Obstruction in Pancreatic Cancer.Digestive diseases and sciences · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND
objectivesEUS-guided biliary drainage (EUS-BD) has recently been used for the treatment of not only malignant pancreaticobiliary diseases, but also for benign diseases. In most previous studies, EUS-BD was performed using a fully covered self-expandable metallic stent (SEMS), and data focusing on the usability of plastic stents for benign diseases are limited. We previously developed a plastic stent dedicated to EUS-guided hepaticoenterostomy (EUS-HES), and achieved favorable results in a feasibility study, although most of the patients had malignant diseases. Therefore, the aim of the present study was to evaluate the usability of dedicated plastic stents for EUS-HES in patients with benign pancreaticobiliary diseases. PATIENTS AND
methodsA total of 57 consecutive patients (28 men, median age: 68 years; range: 7-90 years) of normal and surgically altered anatomy with benign pancreaticobiliary diseases who underwent EUS-HES using the dedicated plastic stent between Jan. 2015 and Jun. 2020 were retrospectively analyzed. Results: The overall technical success rate of EUS-HES was 92.9% (53/57). Among the 4 cases of technical failure of plastic stent placement, a SEMS was placed in 1; percutaneous transhepatic biliary drainage was performed in 1; EUS-HES was reperformed 1 week later in 1; and observational management was selected in 1 patient. Adverse events associated with the procedure were seen in 15.7% (9/57) of the patients, namely, biliary peritonitis in 4, bleeding in 2, cholecystitis in 2, and pneumoperitoneum in 1 patient. Except for 1 patient who required blood transfusion owing to bleeding and 1 patient with cholecystitis who required percutaneous transhepatic gallbladder drainage, the other 7 patients were treated by conservative therapy. There were no intervention-associated deaths.
conclusionOur results demonstrated that for patients with benign pancreaticobiliary diseases in whom conventional ERCP was unsuccessful, EUS-HES using a dedicated plastic stent was safe and feasible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.