ArticleJournal of applied clinical medical physics2021
Commissioning of a three-dimensional arc-based technique for total body irradiation.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 2 citations in OpenAlex.
- Three-dimensional printers applied for the production of beam blocks in total body irradiation treatment.Journal of applied clinical medical physics · 2022Article
- Commissioning of a three-dimensional arc-based technique for total body irradiation.Journal of applied clinical medical physics · 2021Article
- Evaluation of Surface Dose and Commissioning of Compensator-Based Total Body Irradiation.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this study is to describe the commissioning of a novel three-dimensional arc-based technique for total body irradiation (TBI) treatments. The development and implementation of this technique allowed our institution to transition from a bilateral two-dimensional (2D) technique to a methodology based on volumetric dose calculation. The methodology described in this work is a derivation from the MATBI technique, with the static fields being replaced by four contiguous arc-fields for each anterior and posterior incidence. The reduced number of fields we employed makes it possible to reach a satisfactory dose uniformity through manual optimization in a straightforward process. We use the Eclipse anisotropic analytical algorithm (AAA) algorithm, commissioned with preconfigured beam data for a 6 MV photon beam, at standard SSD (100 cm). A thorough evaluation of the accuracy of the AAA algorithm at an extended distance (approximately 200 cm) was carried out. For the evaluation, we compared measured and calculated percentage depth-dose and profiles that included open-field, penumbra, and out-of-field regions. The analysis was performed for both static and arc fields, taking into consideration unshielded fields and also in the presence of lung shielding blocks. End-to-end tests were carried out for our institutional template plan by two means: with a 2D ion chamber array detector in solid phantom and using Gafchromic films in an anthropomorphic phantom. The results obtained in this work demonstrate that the Eclipse AAA algorithm commissioned for standard treatments can be safely used with our TBI planning technique. Moreover, this technique proved to be a highly efficient path to replace conventional treatment techniques, providing a homogeneous dose distribution, dosimetric robustness, and shorter treatment times. In addition, as inherited from the MATBI technique, our methodology can be implemented in small treatment rooms, with no need for ancillary equipment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.