Reduce Patient Treatment wait time in a Proton Beam Facility - A Gatekeeper Approach.
Article in Journal of medical systems, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Simulation as a tool to model potential workflow enhancements in radiotherapy treatment pathways - A systematic review.Journal of applied clinical medical physics · 2023Pooled it
- How to adjust the expected waiting time to improve patient's satisfaction?BMC health services research · 2023Trial
- Simulation and optimization of treatment schedule for multi-gantry heavy ion therapy.Technical innovations & patient support in radiation oncology · 2026Article
- An operational key performance indicator framework and reference data from a multi-room pencil beam scanning proton therapy center.PloS one · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Patient wait time can negatively impact treatment quality in a proton therapy center, where multiple treatment rooms share one proton beam. Wait time increases patient discomfort that can lead to patient motion, dissatisfaction, and longer treatment delay. This study was to develop a patient call-back model that reduced patient wait while efficiently utilizing the proton beam. A "Gatekeeper" logic allowing therapists to adjust the time of a patient's call-back to the treatment room was developed. It uses a two-pronged approach to minimize overlap of long treatment and the possibility of excessive wait in the queue to receive the proton beam. The goal was to reduce the maximum wait time to less than eight minutes per field for a four-room facility. The effectiveness of this logic was evaluated through simulation, and five scenarios were compared. Four scenarios implementing various levels of gatekeeper logic were compared with the original scenario without the logic. The best performing model provided a reduction of the maximum field wait by 26% and met the predefined goal. Adjusting call-back extended the treatment day length by an average of 6 min and a maximum of 12 min in total. The use of this gatekeeper logic significantly reduces patient field wait with minimal impact on treatment day length for a four-room proton facility. A sample interface that adopts this logic for therapists to make informed decision on patient call-back time is demonstrated.