ArticleJournal of healthcare engineering2021
Fuzzy PID Control for Respiratory Systems.
Article in Journal of healthcare engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Adaptive Content Tuning of Social Network Digital Health Interventions Using Control Systems Engineering for Precision Public Health: Cluster Randomized Controlled Trial.Journal of medical Internet research · 2023Trial
- Evaluation of flow control using PID versus fuzzy logic in an electropneumatic circuit for pulmonary ventilation applications.PloS one · 2025Article
- Machine learning algorithm for ventilator mode selection, pressure and volume control.PloS one · 2024Article
- Self-Regulating Adaptive Controller for Oxygen Support to Severe Respiratory Distress Patients and Human Respiratory System Modeling.Diagnostics (Basel, Switzerland) · 2023Article
- Tunicamycin-Induced Endoplasmic Reticulum Stress Promotes Breast Cancer Cell MDA-MB-231 Apoptosis through Inhibiting Wnt/Journal of healthcare engineering · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper presents the implementation of a fuzzy proportional integral derivative (FPID) control design to track the airway pressure during the mechanical ventilation process. A respiratory system is modeled as a combination of a blower-hose-patient system and a single compartmental lung system with nonlinear lung compliance. For comparison purposes, the classical PID controller is also designed and simulated on the same system. According to the proposed control strategy, the ventilator will provide airway flow that maintains the peak pressure below critical levels when there are unknown parameters of the patient's hose leak and patient breathing effort. Results show that FPID is a better controller in the sense of quicker response, lower overshoot, and smaller tracking error. This provides valuable insight for the application of the proposed controller.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.