ArticleJournal of orthopaedic surgery and research2021
Clinical observation and finite element analysis of cannulated screw internal fixation in the treatment of femoral neck fracture based on different reduction quality.
Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Clinical Outcome and Biomechanical Analysis of Dynamic Hip Screw Combined with Derotation Screw in Treating Displaced Femoral Neck Fractures Based on Different Reduction Qualities in Young Patients (≤65 Years of Age).BioMed research international · 2022Trial
- Reliability and agreement study of three-dimensional measurement for femoral head displacement indicators after femoral neck fractures.Scientific reports · 2026Article
- Clinical efficacy of manual reverse closed reduction and robot-assisted cannulated screw fixation for valgus-impacted osteoporotic femoral neck fractures in the elderly: a retrospective cohort study.Frontiers in surgery · 2026Article
- Wider screw spread can reduce the risk of short-term femoral head necrosis by optimizing the fixation stability in femoral neck fracture patients with triangle cannulated screw fixation.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Article
- A Retrospective Study on the Relationship Between Calcar Femorale Injury and Postoperative Complications of Femoral Neck Fracture in Young and Middle-Aged Patients Treated With Three Cannulated Screws.Orthopaedic surgery · 2025Article
- Clinical efficacy comparison of internal fixation of locking compression plate and cannulated screw in treatment of elderly femoral neck fractures-a retrospective study.Frontiers in surgery · 2025Article
- Fracture classification and coronal plane position of bolt may affect the prognosis after femoral neck system (FNS) surgery for femoral neck fractures.BMC surgery · 2024Article
- The ratio between the screw distance and femoral neck width on lateral radiography is a reliable predictor of femoral head necrosis: a clinical review and corresponding numerical simulations.Journal of orthopaedic surgery and research · 2024Article
- Biomechanical effects of FNS on femoral neck fractures based on different reduction quality: finite element analysis.BMC musculoskeletal disorders · 2024Article
- Nonanatomical reduction of femoral neck fractures in young patients with different Pauwels classifications: a retrospective study and finite element analysis.BMC musculoskeletal disorders · 2024Article
- Positive buttress reduction in femoral neck fractures: a literature review.Journal of orthopaedic surgery and research · 2024Review
- Biomechanical investigation of positive reduction in the femoral neck fracture: a finite element analysis.Frontiers in bioengineering and biotechnology · 2024Article
- Biomechanical analysis of a new cannulated screw for unstable femoral neck fractures.Frontiers in bioengineering and biotechnology · 2024Article
- Prediction of hip joint function and analysis of risk factors for internal fixation failure after Femoral Neck System (FNS).BMC musculoskeletal disorders · 2023Article
- Prevention of sclerosis around cannulated screw after treatment of femoral neck fractures with bioceramic nails: a finite element analysis.BMC musculoskeletal disorders · 2023Article
- Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis.BMC musculoskeletal disorders · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
objectiveFemoral neck fracture is one of the most common bone types. The effect of reduction quality on hip joint function and complications after screw internal fixation is not fully understood. To investigate the clinical efficacy and mechanical mechanism of positive buttress, anatomical reduction, and negative buttress in the treatment of femoral neck fracture after cannulated screw fixation.
methodsRetrospective analysis of patients with femoral neck fracture treated with three cannulated screws internal fixation in our hospital from January 2013 to December 2018. According to the quality of fracture reduction, the patients were divided into positive buttress group, anatomical reduction group, and negative buttress group. Basic information such as injury mechanism, time from injury to surgery, Garden classification and Pauwels classification was collected, Harris scores were performed at 3 months, 6 months, and 12 months after surgery, and postoperative complications (femoral head necrosis, femoral neck shortening, and femoral neck nonunion) were collected. At the same time, three groups of finite element models with different reduction quality were established for stress analysis, their stress clouds were observed and the average displacement and stress of the three groups of models were compared. P < 0.05 was used to represent a statistically significant difference.
resultsA total of 225 cases of unilateral femoral neck fractures were included and followed up for an average of 4.12 ± 0.69 years. There was no significant difference in age, gender, side, injury mechanism, time from injury to surgery, BMI, Garden classification, Pauwels classification, and follow-up time among the three groups (P > 0.05). However, there was significant difference in Harris score at 6 and 12 months after operation among the three groups (P < 0.05), which was higher in the positive buttress group and anatomical reduction group than in the negative buttress group. In addition, the incidence of osteonecrosis of the femoral head in the negative buttress group (32.2%) was greater than that in the anatomical reduction group (13.4%) and the positive buttress group (5.4%) (P < 0.05). In addition, the incidence of femoral neck nonunion and femoral neck shortening in the negative buttress group was also higher than that in the anatomical reduction positive buttress group (P < 0.05). The finite element results showed that the stress and fracture end displacement in the negative buttress group were greater than those in the positive buttress group (P < 0.05).
conclusionBoth positive buttress and anatomical reduction in the treatment of femoral neck fracture with cannulated screw internal fixation can obtain better clinical effect and lower postoperative complications. Positive brace support and anatomic reduction can limit the restoration of femoral stress conduction. Therefore, it is not necessary to pursue anatomical reduction too deliberately during surgery, while negative buttress reduction should be avoided.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.