Evidence map›Paper›PMID 34256770›Full record

ArticleBMC musculoskeletal disorders2021

Midterm functional recovery of Total knee arthroplasty patients compared between the ATTUNE knee system and the press fit condylar (PFC) SIGMA knee system.

Ekasame Vanitcharoenkul, Aasis Unnanuntana

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Does lucency equate to revision? A five-year retrospective review of Attune and Triathlon total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ekasame VanitcharoenkulDepartment of Orthopedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Wanglang Road, Bangkoknoi, Bangkok, 10700, Thailand.
Aasis UnnanuntanaDepartment of Orthopedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Wanglang Road, Bangkoknoi, Bangkok, 10700, Thailand. uaasis@gmail.com.ORCID http://orcid.org/0000-0002-5742-298X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe ATTUNE Knee System is a new prosthetic design that has theoretical advantages over the Press Fit Condylar (PFC) Sigma Knee System specific to improved knee kinematics and patellofemoral joint tracking. This study aimed to evaluate functional outcomes compared between the ATTUNE and PFC Sigma designs at a minimum follow-up of 5 years.

methodsWe retrospectively reviewed data from total knee arthroplasty (TKA) patients who received either the ATTUNE or PFC Sigma system during November 2013 to February 2015 at Siriraj Hospital (Bangkok, Thailand). Functional outcomes were evaluated using Timed Up and Go (TUG) test, 2-min walk test (2MWT), modified knee score, numerical rating scale-pain, range of motion (ROM), and rate of anterior knee pain and crepitation at preoperation, 3-months, 1-year, and 5-years postoperatively.

resultsOf 113 patients, 59 and 54 received the PFC Sigma and ATTUNE systems, respectively. At a minimum of 5-years follow-up, all functional outcomes improved significantly from the preoperative period although TUG test and 2MWT declined significantly from 1- to 5-years postoperatively only in the PFC Sigma group. The mean ROM at 5-years postoperatively was significantly higher in ATTUNE than in PFC Sigma; however, the difference was small (116° vs. 110°, respectively; p = 0.041). There were no significant differences in any of the other outcome measurements, including anterior knee pain, clunking, and crepitation, between groups at any study time point.

conclusions​Our results revealed no major differences in functional outcomes between the PFC Sigma and ATTUNE TKA designs at an intermediate-term follow-up of at least 5 years. Longer-term follow-up study is needed to evaluate the benefits of the ATTUNE design relative to polyethylene wear and the rate of aseptic loosening.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisFollow-Up StudiesHumansKnee JointProsthesis DesignRange of Motion, ArticularRetrospective StudiesThailandTreatment OutcomeATTUNEFunctional recoveryPFCPress fit condylarTKATotal knee arthroplasty

Identifiers

PMID34256770
PMCPMC8278715

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked