Evidence map›Paper›PMID 34255939›Full record

SynthesisInternational wound journal2022

Effectiveness of the Lapidus plate system in foot surgery: A PRISMA compliant systematic review.

Daniel López-López, Ricardo Larrainzar-Garijo, Ricardo Becerro De-Bengoa-Vallejo, Marta Elena Losa-Iglesias, Javier Bayod-López

Open access · goldAbstract readSystematic Review
In one paragraph

Synthesis in International wound journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 2 pooled it
1.6field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 2 syntheses or guidelines pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 5 institutions in 1 country.

Daniel López-LópezResearch, Health and Podiatry Group, Department of Health Sciences, Faculty of Nursing and Podiatry, Universidade da Coruña, Ferrol, Spain.ORCID https://orcid.org/0000-0002-9818-6290
Ricardo Larrainzar-GarijoOrthopaedics and Trauma Department, Medicine School, Universidad Complutense, Hospital Universitario Infanta Leonor, Madrid, Spain.ORCID https://orcid.org/0000-0002-0501-2006
Ricardo Becerro De-Bengoa-VallejoFaculty of Nursing, Physiotherapy and Podiatry, Complutense University of Madrid, Madrid, Spain.ORCID https://orcid.org/0000-0003-1568-7602
Marta Elena Losa-IglesiasFaculty of Health Sciences, Universidad Rey Juan Carlos, Madrid, Spain.ORCID https://orcid.org/0000-0001-7588-2069
Javier Bayod-LópezBiomedical Research Networking center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN). Group of Applied Mechanics and Bioengineering (AMB), Aragon Institute of Engineering Research (I3A), Universidad de Zaragoza, Zaragoza, Spain.
Hospital Universitario Infanta Leonor · ESUniversidad Complutense de Madrid · ESUniversidad de Zaragoza · ESUniversidade da Coruña · ESUniversidad Rey Juan Carlos · ES

Funding

Spanish Ministry of Science and Innovation PID2019-108009RB-I00
6 · The paper itself

Abstract

Lapidus arthrodesis is an established standard procedure to correct various foot surgery problems and hallux limitus, hypermobility of the first ray, hallux abductus valgus, and symptomatic lesser metatarsal. After decades, many fixation methods in the orthopaedic surgery industry have been developed for decreasing complications and improving this technique. The aim of this PRISMA compliant systematic review is to analyse the effectiveness of several lapidus plate systems in foot surgery. We have carried out the first systematic review of the relevant published literature so as to systematically evaluate the scientific knowledge available now on this association, assigning predefined eligibility criteria. Fourteen studies were selected which had an overall of 738 cases. The first tarsal metatarsal joint and hallux valgus were treated by the application of different types of Lapidus plate system. The optimal level of the fixation in these procedures is related with the type and system insertion place of the plate with or without screw in each specific foot disease. There is an insufficient number of studies about the effectiveness of the different types of Lapidus plate system in foot surgery, and there is a need to increase outcomes knowledge on the level of the fixation, sort of the system, and insert place in foot surgery.

Indexed as

Hallux ValgusMetatarsal BonesMetatarsophalangeal JointArthrodesisBone ScrewsHumansarthrodesisbone-implant interfacefoothallux

Identifiers

PMID34255939
PMCPMC8874064
OpenAlexW3178654098

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.