Novel non-invasive in-house fabricated wearable system with a hybrid algorithm for fetal movement recognition.

Upekha Delay, Thoshara Nawarathne, Sajan Dissanayake, Samitha Gunarathne, Thanushi Withanage, Roshan Godaliyadda, Chathura Rathnayake, Parakrama Ekanayake, Janaka Wijayakulasooriya

Abstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Upekha DelayDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.ORCID 0000-0002-5729-8376
Thoshara NawarathneDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.
Sajan DissanayakeDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.
Samitha GunarathneDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.
Thanushi WithanageDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.ORCID 0000-0002-1869-1124
Roshan GodaliyaddaDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.
Chathura RathnayakeDepartment of Obstetrics and Gynacology, Faculty of Medicine, University of Peradeniya, Peradeniya, Sri Lanka.
Parakrama EkanayakeDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.
Janaka WijayakulasooriyaDepartment of Electrical and Electronic Engineering, Faculty of Engineering, University of Peradeniya, Peradeniya, Sri Lanka.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fetal movement count monitoring is one of the most commonly used methods of assessing fetal well-being. While few methods are available to monitor fetal movements, they consist of several adverse qualities such as unreliability as well as the inability to be conducted in a non-clinical setting. Therefore, this research was conducted to design a complete system that will enable pregnant mothers to monitor fetal movement at home. This system consists of a non-invasive, non-transmitting sensor unit that can be fabricated at a low cost. An accelerometer was utilized as the primary sensor and a micro-controller based circuit was implemented. Clinical testing was conducted utilizing this sensor unit. Two phases of clinical testing procedures were done and during the first phase readings from 120 mothers were taken while during the second phase readings from 15 mothers were taken. Validation was done by conducting an abdominal ultrasound scan which was utilized as the ground truth during the second phase of the clinical testing procedure. A clinical survey was also conducted in parallel with clinical testings in order to improve the sensor unit as well as to improve the final system. Four different signal processing algorithms were implemented on the data set and the performance of each was compared with each other. Out of the four algorithms three algorithms were able to obtain a true positive rate around 85%. However, the best algorithm was selected on the basis of minimizing the false positive rate. Consequently, the most feasible as well as the best performing algorithm was determined and it was utilized in the final system. This algorithm have a true positive rate of 86% and a false positive rate of 7% Furthermore, a mobile application was also developed to be used with the sensor unit by pregnant mothers. Finally, a complete end to end method to monitor fetal movement in a non-clinical setting was presented by the proposed system.

Indexed as

AlgorithmsAdultFemaleFetal MonitoringFetal MovementHumansMiddle AgedWearable Electronic Devices

Identifiers

PMID34255780
PMCPMC8277045

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.