ArticleAJNR. American journal of neuroradiology2021
Carotid Stenting without Embolic Protection Increases Major Adverse Events: Analysis of the National Surgical Quality Improvement Program.
Article in AJNR. American journal of neuroradiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 26 citations in OpenAlex.
- CIRSE Standards of Practice on Carotid Artery Stenting.Cardiovascular and interventional radiology · 2024Guideline
- Systematic Review and Meta-analysis of Radial or Femoral Access for Carotid Stenting.Clinical neuroradiology · 2024Pooled it
- Direct carotid stenting with minimal predilation after embolic protection device crossing failure in cervical internal carotid artery dissection: A case report.Surgical neurology international · 2026Article
- Early Clinical Experience with Carotid Artery Stenting for Internal Carotid Artery Stenosis Using the Protcas GW Protection System.Journal of neuroendovascular therapy · 2026Article
- Contemporary carotid artery stenting practices and peri-procedural outcomes in different European countries: ROADSAVER study multicentric insights.CVIR endovascular · 2025Article
- Outcomes of Carotid Artery Stenting without Embolic Protection in Yemen: A Resource-Constrained Experience.Journal of neuroendovascular therapy · 2025Article
- Transradial Access Versus Transfemoral Approach for Carotid Artery Stenting: A Systematic Review and Meta-Analysis.Stroke (Hoboken, N.J.) · 2024Article
- Mid-Term Results of an Italian Multicentric Experience with the RoadsaverHealthcare (Basel, Switzerland) · 2024Article
- Lessons From ACST-2.Stroke · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposePublished data regarding embolic protection device efficacy is mixed, and its use during carotid artery stent placement remains variable. We, therefore, examined the frequency of embolic protection device use and its association with outcomes after carotid artery stent placement using a national quality improvement data base. MATERIALS AND
methodsPatients undergoing carotid artery stent placement with or without embolic protection devices were identified in the American College of Surgeons National Surgical Quality Improvement Program data base. The primary outcome was the incidence of major adverse cardiovascular events (defined as death, stroke, or myocardial infarction/arrhythmia) within 30 days. Propensity scoring was used to create 2 matching cohorts of patients using demographic and baseline variables.
resultsBetween 2011 and 2018, among 1200 adult patients undergoing carotid artery stent placement, 23.8% did not have embolic protection devices. There was no trend toward increased embolic protection device use with time. Patients without embolic protection device use received preoperative antiplatelets less frequently (90.6% versus 94.6%,
conclusionsLack of embolic protection device use during carotid artery stent placement is associated with a 4-fold increase in the likelihood of perioperative stroke. Nevertheless, nearly one-quarter of patients in the American College of Surgeons National Surgical Quality Improvement Program underwent unprotected carotid artery stent placement. Efforts targeting improved embolic protection device use during carotid artery stent placement are warranted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.