Evidence map›Paper›PMID 34252265›Full record

ArticleInternational journal of laboratory hematology2021

A performance evaluation of chemiluminescence enzyme immunoassays on the Sysmex CN-6500 haemostasis analyser.

Chris Gardiner, Philip Lane, Hitesh Tailor, Samuel J Machin, Ian J Mackie

Open access · hybridAbstract read
In one paragraph

Article in International journal of laboratory hematology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Chris GardinerResearch Department of Haematology, University College London, London, UK.ORCID https://orcid.org/0000-0002-2318-0062
Philip LaneResearch Department of Haematology, University College London, London, UK.
Hitesh TailorHaematology Evaluations Unit, HSL (Analytics) LLP, London, UK.ORCID https://orcid.org/0000-0003-3615-7889
Samuel J MachinResearch Department of Haematology, University College London, London, UK.
Ian J MackieResearch Department of Haematology, University College London, London, UK.ORCID https://orcid.org/0000-0002-7393-2365
University College London · GBRoyal Buckinghamshire Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Sysmex CN-6500 is a new haemostasis analyser with an integrated immunoassay module that performs chemiluminescence enzyme assay (CLEIA) in addition to coagulation, turbidimetric, chromogenic and platelet aggregation tests.

aimsTo evaluate the analytical performance of the CN-6500 against the predicate device (Sysmex HISCL-800) for soluble thrombomodulin (TM), thrombin-antithrombin (TAT), tissue plasminogen activator/plasminogen activator inhibitor 1 complex (tPAI-C) and plasmin α2 plasmin inhibitor complex (PIC) assays.

methodsImprecision was assessed by testing two levels of quality control plasmas 10 times on 5 separate days. Comparability was studied in 230 plasmas from normal donors (n = 30), patients with suspected disseminated intravascular coagulation (DIC, n = 100), sepsis (n = 20) or liver disease (n = 20), lipaemic (n = 20), haemolysed (n = 20) and icteric samples (n = 20). Limit of detection, limit of quantitation and linearity were determined by testing serial dilutions of normal plasma. Sample carryover was assessed by testing samples with high and low normal levels of the analytes concerned.

resultsThe CN-6500 performed 21 CLEIA tests per hour, while simultaneously performing coagulation tests. Acceptable between-run imprecision was obtained using commercial controls with normal and high activity for each analyte (%CV <4%), for all four assays. Excellent linearity was observed (slope 0.89-1.03; r

conclusionsOur data demonstrate that the performance of the CLEIA assays on the CN-6500 is comparable to that of a stand-alone immunoassay analyser.

Indexed as

Automation, LaboratoryBlood CoagulationBlood Coagulation TestsHumansImmunoenzyme TechniquesLuminescent MeasurementsReproducibility of ResultsSensitivity and SpecificitycoagulationDICfibrinolysislaboratory automation

Identifiers

PMID34252265
PMCPMC9292606
OpenAlexW3177840534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked