Evidence map›Paper›PMID 34251418›Full record

ArticleJournal of biomechanical engineering2022

Hemodynamically Unloading the Distal Pulmonary Circulation in Pulmonary Hypertension: A Modeling Study.

Rachelle Walter, Kendall Hunter, Kurt Stenmark, Vitaly O Kheyfets

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanical engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact, top 88% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Rachelle WalterDepartment of Bioengineering, University of Colorado Anschutz Medical Campus, Aurora, CO 80045.
Kendall HunterDepartment of Bioengineering and Department of Pediatrics, University of Colorado Anschutz Medical Campus, Children's Hospital Colorado, Aurora, CO 80045.
Kurt StenmarkDivision of Pediatric Critical Care Medicine and Cardiovascular Pulmonary Research, University of Colorado Anschutz Medical Campus, Children's Hospital Colorado, Aurora, CO 80045.
Vitaly O KheyfetsDepartment of Bioengineering and Department of Pediatrics, University of Colorado Anschutz Medical Campus, Children's Hospital Colorado, Aurora, CO 80045.
University of Colorado Denver · USChildren's Hospital Colorado · USUniversity of Colorado Anschutz Medical Campus · US

Funding

What triggers RV Fiber Re-Orientation in response to RV pressure overload, and what is its Consequence on Inter-Ventricular Decoupling?R01HL152250 · NHLBI · UNIVERSITY OF COLORADO DENVER · PI Vitaly Kheyfets · 2023 to 2026
$1.9M
Inter-ventricular decoupling is an overlooked contributor to right ventricular myocardial stress and dysfunction in pediatric pulmonary hypertensionK25HL133481 · NHLBI · UNIVERSITY OF COLORADO DENVER · PI KHEYFETS, VITALY · 2017 to 2021
$605k
Cause and effect of transient changes in stress, gene expression, and RV fiber orientation during RV remodeling, and its impact on RV function and inter-ventricular coupling in pulmonary hypertensionR56HL152250 · NHLBI · UNIVERSITY OF COLORADO DENVER · PI KHEYFETS, VITALY · 2021 to 2021
$404k
NHLBI NIH HHS K25 HL133481NHLBI NIH HHS NHLBI K25 HL33481NHLBI NIH HHS R01 HL152250NHLBI NIH HHS R56 HL152250
6 · The paper itself

Abstract

Pulmonary hypertension (PH) is a progressive disease that is characterized by a gradual increase in both resistive and reactive pulmonary arterial (PA) impedance. Previous studies in a rodent model of PH have shown that reducing the hemodynamic load in the left lung (by banding the left PA) reverses this remodeling phenomenon. However, banding a single side of the pulmonary circulation is not a viable clinical option, so-using in silico modeling-we evaluated if the banding effect can be recreated by replacing the proximal vasculature with a compliant synthetic PA. We developed a computational model of the pulmonary circulation by combining a one-dimensional model of the proximal vasculature with a zero-dimensional line transmission model to the 12th generation. Using this model, we performed four simulations: (1) Control; (2) PH; (3) PH with a stenosis in the left PA; and (4) PH with proximal vessel compliance returned to Control levels. Simulations revealed that vascular changes associated with PH result in an increase in pulse pressure (PP), maximum pressure (Pmax), maximum wall shear stress (WSS), and maximum circumferential stress (σθθ) relative to controls, in the distal circulation. Banding the left PA reduced these measurements of hemodynamic stress in the left lung, but increases them in the right lung. Furthermore, left PA banding increased reactive PA impedance. However, returning the proximal PA compliance to Control levels simultaneously decreased all measures of hemodynamic stress in both lungs, and returned reactive PA impedance to normal levels. In conclusion, if future in vivo studies support the idea of hemodynamic unloading as an effective therapy for PH, this can be surgically achieved by replacing the proximal PA with a compliant prosthesis, and it will have the added benefit of reducing reactive right ventricular afterload.

Indexed as

Hypertension, PulmonaryHemodynamicsHumansPulmonary ArteryPulmonary CirculationVascular Resistance

Identifiers

PMID34251418
PMCPMC8547017
OpenAlexW3178789463

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.