Evidence map›Paper›PMID 34249612›Full record

ArticleJournal of orthopaedic translation2021

Verification and clinical translation of a newly designed "Skywalker" robot for total knee arthroplasty: A prospective clinical study.

Runzhi Xia, Zanjing Zhai, Jingwei Zhang, Degang Yu, Liao Wang, Yuanqing Mao, Zhenan Zhu, Haishan Wu, Kerong Dai, Mengning Yan and 1 more

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic translation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 1 pooled it
4.6field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. [A multicenter randomized controlled trial of domestic robot-assisted and conventional total knee arthroplasty].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Robotic Total Knee Arthroplasty: An Update.Journal of personalized medicine · 2024
    Review
  12. Article
  13. Article
  14. [A comparative study of short-term effectiveness of "SkyWalker" robot-assisted versus traditional total knee arthroplasty].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Runzhi XiaShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Zanjing ZhaiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Jingwei ZhangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Degang YuShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Liao WangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Yuanqing MaoShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Zhenan ZhuShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Haishan WuShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Kerong DaiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Mengning YanShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Huiwu LiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China.
Shanghai Ninth People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate accuracy of an innovative "Skywalker" system, a newly designed, robot-assisted operation system for orthopaedics via a clinical trial at knee joint.

methodsWe conducted a prospective analysis of the clinical data of 31 patients who underwent total knee arthroplasty assisted by the "Skywalker" robot (Microport, Suzhou, China) from June 2020 to January 2021. Five male patients and 26 female patients aged 69.68 ​± ​6.11 years (range: 57-79 years) were diagnosed with knee osteoarthritis and indicated for surgery. The "Skywalker" surgical robotic system was adopted to make a preoperative plan for knee arthroplasty. When the robotic arm reached the specified position during the operation, a single surgeon performed the osteotomy with a cutting saw through the cutting jig, and the difference between the actual and the expected resection thickness, and the preoperative and postoperative lower limb alignments were measured.

resultsThe actual error of the resection thickness was the difference between the actual and the expected resection thickness. The absolute error of the resection thickness was the absolute value of the actual error of resection thickness. The absolute errors of the resection thickness of the medial and lateral condyle of the distal femur, the medial and lateral posterior condyle of the femur, and the medial and lateral sides of the tibial plateau were 0.87 ​± ​0.63 ​mm, 1.02 ​± ​0.67 ​mm, 0.74 ​± ​0.46 ​mm, 0.98 ​± ​0.81 ​mm, 0.92 ​± ​0.66 ​mm, and 1.04 ​± ​0.84 ​mm, respectively. The absolute angle errors between the actual postoperative angles and the preoperative planned angles of the lower limb alignment angles, coronal femoral component angles, and coronal tibial component angles were 1.46° ​± ​0.95°, 1.13° ​± ​1.01°, and 1.05° ​± ​0.73°, respectively. Besides, 100% of the absolute error of the HKA angles was within 3°. In addition, compared to the preoperative lower limb alignment angle, 90.32% of the postoperative lower limb alignment angles of 31 patients were closer to 180° after the operation. All 31 patients underwent a successful surgery, and no relevant complications occurred after the operation, such as surgical site infection, deep venous thrombosis, or vascular and nerve injury.

conclusionThe "Skywalker" system has good osteotomy accuracy, can achieve the planned angles well, and is expected to assist surgeons in performing accurate bone cuts and reconstructing planned lower limb alignments in the relevant clinical applications in future.

Indexed as

AccuracyKnee osteoarthritisRobotic surgical proceduresTotal knee arthroplasty

Identifiers

PMID34249612
PMCPMC8242054
OpenAlexW3176764086

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.