ArticleBiomedical engineering online2021
Evaluation of dry textile electrodes for long-term electrocardiographic monitoring.
Article in Biomedical engineering online, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Performance comparison of conductive textile electrodes in ECG monitoring.Frontiers in bioengineering and biotechnology · 2026Article
- Development and Experimental Validation of an Integrated Evaluation Framework for EMS Smartwear Electrodes.Sensors (Basel, Switzerland) · 2025Article
- Closed-Loop Recycling of Wearable Electronic Textiles.Small (Weinheim an der Bergstrasse, Germany) · 2024Article
- Minimization of Parasitic Capacitance between Skin and Ag/AgCl Dry Electrodes.Micromachines · 2024Article
- Motion artefact management for soft bioelectronics.Nature reviews bioengineering · 2024Article
- Design, Fabrication, and Evaluation of 3D Biopotential Electrodes and Intelligent Garment System for Sports Monitoring.Sensors (Basel, Switzerland) · 2024Article
- Benchtop Performance of Novel Mixed Ionic-Electronic Conductive Electrode Form Factors for Biopotential Recordings.Sensors (Basel, Switzerland) · 2024Article
- Measuring Surface Electromyography with Textile Electrodes in a Smart Leg Sleeve.Sensors (Basel, Switzerland) · 2024Article
- Multichannel microneedle dry electrode patches for minimally invasive transdermal recording of electrophysiological signals.Microsystems & nanoengineering · 2024Article
- Electrospun Rubber Nanofiber Web-Based Dry Electrodes for Biopotential Monitoring.Sensors (Basel, Switzerland) · 2023Article
- Recent Advances and Challenges in Textile Electrodes for Wearable Biopotential Signal Monitoring: A Comprehensive Review.Biosensors · 2023Review
- Evaluation of Novel Embroidered Textile-Electrodes Made from Hybrid Polyamide Conductive Threads for Surface EMG Sensing.Sensors (Basel, Switzerland) · 2023Article
- Fabrication of Textile-Based Dry Electrode and Analysis of Its Surface EMG Signal for Applying Smart Wear.Polymers · 2022Article
- Mucosa-interfacing electronics.Nature reviews. Materials · 2022Review
- Exploring textile-based electrode materials for electromyography smart garments.Journal of rehabilitation and assistive technologies engineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
backgroundContinuous long-term electrocardiography monitoring has been increasingly recognized for early diagnosis and management of different types of cardiovascular diseases. To find an alternative to Ag/AgCl gel electrodes that are improper for this application scenario, many efforts have been undertaken to develop novel flexible dry textile electrodes integrated into the everyday garments. With significant progresses made to address the potential issues (e.g., low signal-to-noise ratio, high skin-electrode impedance, motion artifact, and low durability), the lack of standard evaluation procedure hinders the further development of dry electrodes (mainly the design and optimization).
resultsA standard testing procedure and framework for skin-electrode impedance measurement is demonstrated for the development of novel dry textile electrodes. Different representative electrode materials have been screen-printed on textile substrates. To verify the performance of dry textile electrodes, impedance measurements are conducted on an agar skin model using a universal setup with consistent frequency and pressure. In addition, they are demonstrated for ECG signals acquisition, in comparison to those obtained using conventional gel electrodes.
conclusionsDry textile electrodes demonstrated similar impedance when in raised or flat structures. The tested pressure variations had an insignificant impact on electrode impedance. Looking at the effect of impedance on ECG signals, a noticeable effect on ECG signal performance metrics was not observed. Therefore, it is suggested that impedance alone is possibly not the primary indicator of signal quality. As well, the developed methods can also serve as useful guidelines for future textile dry-electrode design and testing for practical ECG monitoring applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials