Evidence map›Paper›PMID 34246222›Full record

ArticleBMC anesthesiology2021

Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference.

Ramakrishna Mukkamala, Benjamin A Kohl, Aman Mahajan

Abstract readComparative Study
In one paragraph

Article in BMC anesthesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Not all pulse contour algorithms are created equal.Critical care (London, England) · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ramakrishna MukkamalaDepartment of Anesthesiology and Perioperative Medicine and Department of Bioengineering, University of Pittsburgh, 408 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA. rmukkamala@pitt.edu.
Benjamin A KohlDepartment of Anesthesiology, Thomas Jefferson University, Philadelphia, PA, USA.
Aman MahajanDepartment of Anesthesiology and Perioperative Medicine and Department of Bioengineering, University of Pittsburgh, A-1305 Scaife Hall, 3550 Terrace Street, Pittsburgh, PA, 15261, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiac output (CO) is a key measure of adequacy of organ and tissue perfusion, especially in critically ill or complex surgical patients. CO monitoring technology continues to evolve. Recently developed CO monitors rely on unique algorithms based on pulse contour analysis of an arterial blood pressure (ABP) waveform. The objective of this investigation was to compare the accuracy of two monitors using different methods of pulse contour analysis - the Retia Argos device and the Edwards Vigileo-FloTrac device - with pulmonary artery catheter (PAC)-thermodilution as a reference.

methodsFifty-eight patients undergoing off-pump coronary artery bypass surgery formed the study cohort. A total of 572 triplets of CO measurements from each device - Argos, Vigileo-FloTrac (third generation), and thermodilution - were available before and after interventions (e.g., vasopressors, fluids, and inotropes). Bland-Altman analysis accounting for repeated measurements per subject and concordance analysis were applied to assess the accuracy of the CO values and intervention-induced CO changes of each pulse contour device against thermodilution. Cluster bootstrapping was employed to statistically compare the root-mean-squared-errors (RMSE = √(μ

resultsThe RMSE (mean (95% confidence intervals)) for CO values was 1.16 (1.00-1.32) L/min for the Argos device and 1.54 (1.33-1.77) L/min for the Vigileo-FloTrac device; the concordance rate for intervention-induced CO changes was 87 (82-92)% for the Argos device and 72 (65-78)% for the Vigileo-FloTrac device; and the RMSE for the CO changes was 17 (15-19)% for the Argos device and 21 (19-23)% for the Vigileo-FloTrac device (p < 0.0167 for all comparisons).

conclusionsIn comparison with CO measured by the PAC, the Argos device proved to be more accurate than the Vigileo-FloTrac device in CO trending and absolute CO measurement in patients undergoing off-pump coronary artery bypass surgery.

Indexed as

AgedArterial PressureCardiac OutputCatheterization, Swan-GanzCohort StudiesCoronary Artery Bypass, Off-PumpEquipment DesignFemaleHumansMaleMiddle AgedMonitoring, IntraoperativeThermodilutionArgosCardiac output monitoringFloTracPulse contour analysisThermodilution

Identifiers

PMID34246222
PMCPMC8272317

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.