Evidence map›Paper›PMID 34245061›Full record

ArticleHuman brain mapping2021

Optimal design of on-scalp electromagnetic sensor arrays for brain source localisation.

Leandro Beltrachini, Nicolas von Ellenrieder, Roland Eichardt, Jens Haueisen

Abstract read
In one paragraph

Article in Human brain mapping, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Spatial-Jitter Model for Magnetoencephalography Sensor Arrays.IEEE transactions on medical imaging · 2026
    Article
  2. Article
  3. Enhanced Neural Decoding With Optically Pumped Magnetometer MEG Using Multivariate Pattern Analysis.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. A minimum assumption approach to MEG sensor array design.Physics in medicine and biology · 2023
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Leandro BeltrachiniCardiff University Brain Research Imaging Centre (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff.ORCID 0000-0003-4602-1416
Nicolas von EllenriederMontreal Neurological Institute and Hospital, McGill University, Montreal, Canada.
Roland EichardtInstitute of Biomedical Engineering and Informatics, Ilmenau University of Technology, Ilmenau, Germany.
Jens HaueisenInstitute of Biomedical Engineering and Informatics, Ilmenau University of Technology, Ilmenau, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optically pumped magnetometers (OPMs) are quickly widening the scopes of noninvasive neurophysiological imaging. The possibility of placing these magnetic field sensors on the scalp allows not only to acquire signals from people in movement, but also to reduce the distance between the sensors and the brain, with a consequent gain in the signal-to-noise ratio. These advantages make the technique particularly attractive to characterise sources of brain activity in demanding populations, such as children and patients with epilepsy. However, the technology is currently in an early stage, presenting new design challenges around the optimal sensor arrangement and their complementarity with other techniques as electroencephalography (EEG). In this article, we present an optimal array design strategy focussed on minimising the brain source localisation error. The methodology is based on the Cramér-Rao bound, which provides lower error bounds on the estimation of source parameters regardless of the algorithm used. We utilise this framework to compare whole head OPM arrays with commercially available electro/magnetoencephalography (E/MEG) systems for localising brain signal generators. In addition, we study the complementarity between EEG and OPM-based MEG, and design optimal whole head systems based on OPMs only and a combination of OPMs and EEG electrodes for characterising deep and superficial sources alike. Finally, we show the usefulness of the approach to find the nearly optimal sensor positions minimising the estimation error bound in a given cortical region when a limited number of OPMs are available. This is of special interest for maximising the performance of small scale systems to ad hoc neurophysiological experiments, a common situation arising in most OPM labs.

Indexed as

AdultBrainBrain MappingElectroencephalographyHumansMagnetoencephalographyMagnetometryarray processingCramér-Rao boundelectroencephalographymagnetoencephalographyoptically pumped magnetometerssource localisation

Identifiers

PMID34245061
PMCPMC8449117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.