Evidence map›Paper›PMID 34244909›Full record

ArticleMikrochimica acta2021

Nitrogen-doped carbon dots for dual-wavelength excitation fluorimetric assay for ratiometric determination of phosalone.

Xiufen Liao, Congjin Chen, Jielun Yang, Ruxia Zhou, Lulu Si, Quanlong Huang, Zuqiang Huang, Chunqiu Lv

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xiufen LiaoSchool of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China.
Congjin ChenSchool of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China. gxdxccj@163.com.ORCID http://orcid.org/0000-0002-4881-4762
Jielun YangSchool of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China.
Ruxia ZhouSchool of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China.
Lulu SiTechnical Center of Nanning Customs District, Nanning, 530021, China.
Quanlong HuangSchool of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China.
Zuqiang HuangSchool of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China.
Chunqiu LvTechnical Center of Nanning Customs District, Nanning, 530021, China.

Funding

Guangxi Key Laboratory of Petrochemical Resource Processing and Process Intensification Technology, Guangxi University 2020K003National Natural Science Foundation of China 31660183Natural Science Foundation of Guangxi Province 2015GXNSFAA139023Scientific Research Foundation of Guangxi University XJPZ160713
6 · The paper itself

Abstract

N-doped carbon dots (N-CDs) were fabricated in a simple procedure by hydrothermal treatment of cellobiose and urea. When excited at 235 nm or 327 nm, only one emission peak at around 420 nm has been observed. With the addition of phosalone, the excitation band at 235 nm was efficiently quenched within 1 min, while the excitation band at 327 nm showed little change. Accordingly, the fluorescence of the N-CDs-phosalone mixture showed quenching under 254-nm UV light, while nearly no fluorescence quenching could be observed under 365-nm UV light. This phenomenon provides a novel anti-false-positive mechanism for phosalone identification. Therefore, the label-free ratiometric sensor for rapid, naked-eye, and anti-false-positive detection of phosalone was proposed for the first time based on the intrinsic dual-excitation N-CDs. Under the optimum experimental conditions, the linear ranges of the excitation-based ratiometric assay were 0.08~4.0 μg/mL and 4.0~14.0 μg/mL; the limit of detection was 28.5 ng/mL. The as-constructed sensor was applied to detect phosalone residue in actual samples, and results were compared with the standard gas chromatographic (GC) method. The recoveries of the established sensor were between 90.0% and 110.0% with RSD lower than 6.6%, while that for the GC method was between 92.5% and 113.0% with RSD lower than 5.8%. Results reveal that the accuracy (recovery) and precision (RSD) of the as-constructed method are comparable to the standard GC method. In this paper, dual-excitation N-doped carbon dots (N-CDs) were synthesized by a simply one-step hydrothermal method for the first time. The novel dual-excitation ratiometric sensor based on the sole intrinsic N-CDs was constructed for phosalone sensing.

Indexed as

ArtocarpusCactaceaeCarbonFluorescence Resonance Energy TransferFluorescent DyesFood ContaminationIpomoeaLimit of DetectionNitrogenOrganothiophosphorus CompoundsPesticide ResiduesQuantum DotsCarbonFluorescent DyesNitrogenOrganothiophosphorus CompoundsPesticide ResiduesphosaloneCarbon dotsDual-excitationFluorescence assayPhosaloneRatiometric detection

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.