Evidence map›Paper›PMID 34244127›Full record

ArticleAJNR. American journal of neuroradiology2021

Evaluation of Ultrafast Wave-Controlled Aliasing in Parallel Imaging 3D-FLAIR in the Visualization and Volumetric Estimation of Cerebral White Matter Lesions.

C Ngamsombat, A L M Gonçalves Filho, M G F Longo, S F Cauley, K Setsompop, J E Kirsch, Q Tian, Q Fan, D Polak, W Liu and 6 more

Open access · hybridAbstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 19 citations in OpenAlex.

  1. Accelerated 3D MRI for ARIA monitoring in Alzheimer's disease.Alzheimer's & dementia : the journal of the Alzheimer's Association · 2026
    Article
  2. Ultra-fast MRI for dementia diagnosis and treatment eligibility: A prospective study.Alzheimer's & dementia : the journal of the Alzheimer's Association · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Spiral 2D T2-Weighted TSE Brain MR Imaging: Initial Clinical Experience.AJNR. American journal of neuroradiology · 2021
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 4 institutions in 4 countries.

C NgamsombatFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0001-5055-0711
A L M Gonçalves FilhoFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0002-5092-2754
M G F LongoFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0001-6819-4890
S F CauleyFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0002-6147-6016
K SetsompopFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0003-0455-7634
J E KirschFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0002-0389-9475
Q TianFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0002-8350-5295
Q FanFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0001-9053-6279
D PolakAthinoula A. Martinos Center for Biomedical Imaging (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F, D.P., J.C., S.Y.H.), Massachusetts General Hospital, Boston, Massachusetts.ORCID 0000-0001-9781-1528
W LiuSiemens Shenzhen Magnetic Resonance Ltd (W.L.), Shenzhen, China.ORCID 0000-0002-8072-7116
W-C LoSiemens Healthcare GmbH, (D.P., W.-C.L.), Erlangen, Germany.ORCID 0000-0002-1893-0500
R Gilberto GonzálezFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0002-0234-3897
P W SchaeferFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0002-4222-6134
O RapalinoFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0002-5038-4183
J ConklinFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.).ORCID 0000-0001-9921-2086
S Y HuangFrom the Department of (C.N., A.L.M.G.F., M.G.F.L., S.F.C., K.S., J.E.K., Q.T., Q.F., R.G.G., P.W.S., O.R., J.C., S.Y.H.) susie.huang@mgh.harvard.edu.ORCID 0000-0003-2950-7254
United States Nuclear Regulatory Commission · USHeidelberg University · DESiemens (Germany) · DESiemens Healthineers (Germany) · DE

Funding

Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Bruce Fischl · 2020 to 2026
$10.9M
Toward a Validated in Vivo Imaging Marker of Axonal Damage Predictive of Progressive Disability in Multiple SclerosisR01NS118187 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI HUANG, SUSIE YI · 2021 to 2025
$2.8M
Rapid MRI acquisition for pediatric low-grade gliomasR01EB020613 · NIBIB · STANFORD UNIVERSITY · PI SETSOMPOP, KAWIN · 2016 to 2019
$2.5M
Characterizing axonal damage in multiple sclerosis using TractCaliber MRIK23NS096056 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI HUANG, SUSIE YI · 2016 to 2020
$877k
NIBIB NIH HHS P41 EB030006NIBIB NIH HHS R01 EB020613NINDS NIH HHS K23 NS096056NINDS NIH HHS R01 NS118187
6 · The paper itself

Abstract

background and purposeOur aim was to evaluate an ultrafast 3D-FLAIR sequence using Wave-controlled aliasing in parallel imaging encoding (Wave-FLAIR) compared with standard 3D-FLAIR in the visualization and volumetric estimation of cerebral white matter lesions in a clinical setting. MATERIALS AND

methodsForty-two consecutive patients underwent 3T brain MR imaging, including standard 3D-FLAIR (acceleration factor = 2, scan time = 7 minutes 50 seconds) and resolution-matched ultrafast Wave-FLAIR sequences (acceleration factor  = 6, scan time = 2 minutes 45 seconds for the 20-channel coil; acceleration factor = 9, scan time  = 1 minute 50 seconds for the 32-channel coil) as part of clinical evaluation for demyelinating disease. Automated segmentation of cerebral white matter lesions was performed using the Lesion Segmentation Tool in SPM. Student

resultsStandard and Wave-FLAIR sequences showed excellent agreement of lesion volumes with an intraclass correlation coefficient of 0.99 and mean Dice similarity coefficient of 0.97 (SD, 0.05) (range, 0.84-0.99). Wave-FLAIR was noninferior to standard FLAIR for visualization of lesions and motion. The diagnostic quality for Wave-FLAIR was slightly greater than for standard FLAIR for infratentorial lesions (

conclusionsUltrafast Wave-FLAIR provides superior visualization of infratentorial lesions while preserving overall diagnostic quality and yields white matter lesion volumes comparable with those estimated using standard FLAIR. The availability of ultrafast Wave-FLAIR may facilitate the greater use of 3D-FLAIR sequences in the evaluation of patients with suspected demyelinating disease.

Indexed as

BrainWhite MatterArtifactsHumansMagnetic Resonance ImagingMotion

Identifiers

PMID34244127
PMCPMC8423041
OpenAlexW3178802276

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.