Evidence map›Paper›PMID 34239834›Full record

ArticleJournal of orthopaedic case reports2021

Massive Eccentric Wear of the Acetabular Cup after Polyethylene Liner Abrasion in Hip Arthroplasty may lead to a high Risk of Injury during Revision Surgery.

Daniel Burger, Andrej M Nowakowski

Abstract readCase Reports
In one paragraph

Article in Journal of orthopaedic case reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Metallosis Following Total Hip Arthroplasty: A Case Report.Journal of orthopaedic case reports · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Daniel BurgerDepartment of Orthopaedics, Spital Uster, Brunnenstrasse, Uster, Switzerland.
Andrej M NowakowskiDepartment of Orthopaedics and Traumatology, Kantonsspital Baselland, Bruderholz, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPolyethylene wear is known to be a major cause of long-term failure after primary hip arthroplasty which results in the activation of an innate immune response with subsequent osteolysis and component loosening. However, polyethylene wear in hip arthroplasty may be asymptomatic for a long time and following massive, eccentric abrasion of the cup with subluxation of the femoral head after fully polyethylene wear has not yet been described. Hereby, we present a case of rapid progressive eccentric wear of the acetabular cup after complete polyethylene liner abrasion in a ceramic-on-polyethylene bearing. CASE REPORT: A 80-year-old-lady presented on our emergency department with a subluxated hip arthroplasty on the right side implanted 30 years ago. The X-ray showed a Zweymüller stem combined with a Gartenmann cup and a ceramic head with excessive eccentric wear of the acetabular cup with razor blade sharp edges after fully polyethylene liner abrasion.

conclusionProgressive eccentric wear of the acetabular cup after fully polyethylene liner abrasion in ceramic-on-polyethylene bearings in hip arthroplasty may be asymptomatic for a long time but may progress rapidly. To prevent patients from extensive revision surgery and the revision surgeon from serious injury due to intraoperatively findings such as razor blade sharp edges, routine long-term follow-up radiographic evaluation is crucial.

Indexed as

abrasive wearcup wearhip arthroplastyinjuryRevision surgery

Identifiers

PMID34239834
PMCPMC8241244

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.