Evidence map›Paper›PMID 34236513›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2022

Reverse distal femoral locking compression plate (DF-LCP), does it fit and how to fit on Asian's proximal femurs? A cadaveric study.

V Apivatthakakul, T Apivatthakakul

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

V ApivatthakakulDepartment of Orthopaedics, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand.
T ApivatthakakulDepartment of Orthopaedics, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand. tapivath@gmail.com.ORCID http://orcid.org/0000-0001-8374-9540

Funding

Faculty of Medicine, Chiang Mai University ORT-2561-05759
6 · The paper itself

Abstract

introductionReverse distal femoral locking compression plates (DF-LCP) have been used as an alternative treatment in complex proximal femur fractures.

objectiveThe purpose of this study was to assess the compatibility of reverse DF-LCP with Asian proximal femurs, to determine the matching patterns and integrate information to establish guidelines for correct application.

methodsTwenty-eight adult cadaveric femurs were obtained from 5 males and 9 females with an average age of 69.27 years (range 59-85). A contralateral 13-hole DF-LCP was applied with MIPO technique using the vastus ridge as a landmark for Hole A. The first locking screw was inserted through Hole A under fluoroscopic guidance just above the femoral head-neck junction in AP view and centered of the neck in lateral view, followed by three proximal locking screws. The number of screws successfully inserted through the femoral neck, including any penetration of femoral neck, the gap between anterior and posterior borders between plate and bone, the anatomical parameters of proximal femur, and any mismatches between the plate and the bone were recorded.

resultsMost of the screws (82.1%) in Holes A, D, E, and F were put into the femoral neck without breaking through. The average distance from the entry point at the vastus ridge to the anterior cortex of the femur was 17.3 ± 2.3 mm and from the posterior cortex was 19.46 ± 2.55 mm. The anterior gap was 4.93 ± 1.01 mm, and the posterior gap was 13.48 ± 1.44 mm. The mismatch where the distal part of the plate started to lift off from the bone > 2 mm at the 8th hole with an average distance of 2.78 ± 2.01 mm. That distance gradually increased distally to an average of 9.38 ± 6.03 mm at the 13th hole.

conclusionsReverse DF-LCP can fit most proximal femurs in the Asian population and can be used as an alternative implant when performed using an appropriate technique. However, as a relatively consistent mismatch was found at the distal part starting at the 8th hole, so if a plate is longer than 9 holes, the plate contouring should be considered.

Indexed as

Femoral FracturesFracture Fixation, InternalAdultAgedAged, 80 and overBone PlatesBone ScrewsCadaverFemaleFemurHumansMaleMiddle AgedAnatomical mismatchDistal femoral locking plate (DF-LCP)FractureProximal femurReverse DF-LCPTechnical guide

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.