Evidence map›Paper›PMID 34236237›Full record

ArticleBone & joint open2021

Hip implants can restore anatomical and medialized rotation centres in most cases : a 3D templating study comparing four implantation strategies.

Thierry Scheerlinck, Elien De Winter, Amelie Sas, Sjoerd Kolk, Gert Van Gompel, Jef Vandemeulebroucke

Open access · goldAbstract read
In one paragraph

Article in Bone & joint open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Thierry ScheerlinckDepartment of Orthopaedic Surgery and Traumatology, Universitair Ziekenhuis Brussel, Brussels, Belgium.
Elien De WinterDepartment of Orthopaedic Surgery and Traumatology, Universitair Ziekenhuis Brussel, Brussels, Belgium.
Amelie SasDepartment of Mechanical Engineering, Katholieke Universiteit Leuven, Leuven, Belgium.
Sjoerd KolkMaterialise Group, Leuven, Belgium.
Gert Van GompelMedische Beeldvorming en Fysische Wetenschappen (BEFY), Vrije Universiteit Brussel, Brussels, Belgium.
Jef VandemeulebrouckeDepartment of Electronics and Informatics (ETRO), Vrije Universiteit Brussel, Brussel, Belgium.
Universitair Ziekenhuis Brussel · BEKU Leuven · BEMaterialise (Belgium) · BEVrije Universiteit Brussel · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsHip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre.

methodsUsing 3D templating software in 49 CT scans of non-deformed femora, we virtually implanted: 1) small uncemented calcar-guided stems with two offset options (Optimys, Mathys), 2) uncemented straight stems with two offset options (Summit, DePuy Synthes), 3) cemented undersized stems (Exeter philosophy) with three offset options (CPT, ZimmerBiomet), and 4) cemented line-to-line stems (Kerboul philosophy) with proportional offsets (Centris, Mathys). We measured the distance between the templated and the anatomical and 5 mm medialized hip rotation centre.

resultsBoth rotation centres could be restored within 5 mm in 94% and 92% of cases, respectively. The cemented undersized stem performed best, combining freedom of stem positioning and a large offset range. The uncemented straight stem performed well because of its large and well-chosen offset range, and despite the need for cortical bone contact limiting stem positioning. The cemented line-to-line stem performed less well due to a small range of sizes and offsets. The uncemented calcar-guided stem performed worst, despite 24 sizes and a large and well-chosen offset range. This was attributed to the calcar curvature restricting the stem insertion depth along the femoral axis.

conclusionIn the majority of non-deformed femora, leg length, offset, and anteversion can be restored accurately with non-modular stems during 3D templating. Failure to restore hip biomechanics is mostly due to surgical inaccuracy. Small calcar guided stems offer no advantage to restore hip biomechanics compared to more traditional designs. Cite this article:

Indexed as

BiomechanicsHip arthroplastyLeg lengthOffsetTemplating

Identifiers

PMID34236237
PMCPMC8325978
OpenAlexW3182838853

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.