Evidence map›Paper›PMID 34235565›Full record

ArticleAnalytical and bioanalytical chemistry2021

In-depth characterization of non-human sialic acid (Neu5Gc) in human serum using label-free ZIC-HILIC/MRM-MS.

Nari Seo, Jaekyoung Ko, Daum Lee, Heejin Jeong, Myung Jin Oh, Unyong Kim, Dong Ho Lee, Jaehan Kim, Yoon Jin Choi, Hyun Joo An

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Isomer-Specific Monitoring of SialylatedFrontiers in molecular biosciences · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Nari SeoGraduate School of Analytical Science and Technology, Chungnam National University, Daejeon, 34134, Republic of Korea.
Jaekyoung KoGraduate School of Analytical Science and Technology, Chungnam National University, Daejeon, 34134, Republic of Korea.
Daum LeeGraduate School of Analytical Science and Technology, Chungnam National University, Daejeon, 34134, Republic of Korea.
Heejin JeongGraduate School of Analytical Science and Technology, Chungnam National University, Daejeon, 34134, Republic of Korea.
Myung Jin OhGraduate School of Analytical Science and Technology, Chungnam National University, Daejeon, 34134, Republic of Korea.
Unyong KimBiocomplete Co., Ltd., Seoul, 08389, Republic of Korea.
Dong Ho LeeDepartment of Internal Medicine, Seoul National University Budang Hospital, Seongnam, 13620, Republic of Korea.
Jaehan KimDepartment of Food and Nutrition, Chungnam National University, Daejeon, 34134, Republic of Korea.
Yoon Jin ChoiDepartment of Internal Medicine, Seoul National University Budang Hospital, Seongnam, 13620, Republic of Korea. yjinchoi@yuhs.ac.
Hyun Joo AnGraduate School of Analytical Science and Technology, Chungnam National University, Daejeon, 34134, Republic of Korea. hjan@cnu.ac.kr.
Chungnam National University · KRSeoul National University Bundang Hospital · KR

Funding

Ministry of Food and Drug Safety 21172MFDS192
6 · The paper itself

Abstract

Sialic acid Neu5Gc, a non-human glycan, is recognized as a new harmful substance that can cause vascular disease and cancer. Humans are unable to synthesize Neu5Gc due to a genetic defect that converts Neu5Ac to Neu5Gc, but Neu5Gc is often observed in human biological samples. Therefore, the demand for accurately measuring the amount of Neu5Gc present in human blood or tissues is rapidly increasing, but there is still no method to reliably quantify trace amounts of a non-human sugar. In particular, selective isolation and detection of Neu5Gc from human serum is analytically challenging due to the presence of excess sialic acid Neu5Ac, which has physicochemical properties very similar to Neu5Gc. Herein, we developed the label-free approach based on ZIC-HILIC/MRM-MS that can enrich sialic acids released from human serum and simultaneously monitor Neu5Ac and Neu5Gc. The combination of complete separation of Neu5Gc from abundant Neu5Ac by hydrophilic and electrostatic interactions with selective monitoring of structure-specific cross-ring cleavage ions generated by negative CID-MS/MS was remarkably effective for quantification of Neu5Ac and Neu5Gc at the femtomole level. Indeed, we were able to successfully determine the absolute quantitation of Neu5Gc from 30 healthy donors in the range of 3.336 ± 1.252 pg/μL (mean ± SD), 10,000 times lower than Neu5Ac. In particular, analysis of sialic acids in protein-free serum revealed that both Neu5Ac and Neu5G are mostly bound to proteins and/or lipids, but not in free form. In addition, the correlation between expression level of Neu5Gc and biological factors such as BMI, age, and sex was investigated. This method can be widely used in studies requiring sialic acid-related measurements such as disease diagnosis or prediction of immunogenicity in biopharmaceuticals as it is both fast and highly sensitive.

Indexed as

Carbohydrate ConformationHumansMass SpectrometrySensitivity and SpecificitySialic AcidsStatic ElectricitySialic AcidsAbsolute quantitationHuman serumLabel-free MRM-MSNeu5GcSialic acid

Identifiers

PMID34235565
OpenAlexW3181046949

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.