Effect of repeated use of an implant handpiece on an output torque: An

KeunBaDa Son, Young-Tak Son, Ji-Young Kim, Jae-Mok Lee, Won-Jae Yu, Jin-Wook Kim, Kyu-Bok Lee

Open access · diamondAbstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 87% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

KeunBaDa SonDepartment of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea.ORCID https://orcid.org/0000-0002-3177-8005
Young-Tak SonDepartment of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea.ORCID https://orcid.org/0000-0001-8893-5369
Ji-Young KimAdvanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu, Republic of Korea.ORCID https://orcid.org/0000-0001-7460-6353
Jae-Mok LeeDepartment of Periodontology, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.ORCID https://orcid.org/0000-0002-0291-6114
Won-Jae YuDepartment of Orthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.ORCID https://orcid.org/0000-0002-6953-3011
Jin-Wook KimDepartment of Oral & Maxillofacial Surgery, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.ORCID https://orcid.org/0000-0003-4074-877X
Kyu-Bok LeeAdvanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu, Republic of Korea.ORCID https://orcid.org/0000-0002-1838-7229
Kyungpook National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque. MATERIALS AND

methodsTwo types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05).

resultsNSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (

conclusionThere may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

Indexed as

Dental implantsImplant handpieceOutput torqueRepeated use

Identifiers

PMID34234923
PMCPMC8250193
OpenAlexW3182734241

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.