ArticleNeurologia medico-chirurgica2021
Triggering of Carotid Sinus Reflex during Deployment of the Flow-diverter Device.
Article in Neurologia medico-chirurgica, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The carotid sinus reflex (CSR) is a rare complication of the Pipeline Embolization Device (PED) deployment. No study has assessed the potential risk factors in a case series. The purpose of this study was to examine CSR triggering during PED deployment. Thirty-seven consecutive patients who underwent PED deployment were included. All procedures were performed under local anesthesia with mild sedation. We retrospectively analyzed patient characteristics, PED deployment time, and vital signs during the procedure. The vital signs included the pulse rate (PR) and systolic blood pressure (SBP) obtained at three timepoints (pre-deployment, during deployment, post-deployment). We examined the triggering of the CSR during PED deployment by comparing the vital signs at the three timepoints. Moreover, risk factors for CSR were analyzed with univariate analysis. The patients' average age was 66.3 years. The average size of the aneurysm was 18.0 mm. Six patients (16.2%) showed a decline in the SBP or PR defined as CSR. One patient had a transient cardiac arrest and two had severe transient bradycardia. Deployment into the ophthalmic segment of the internal carotid artery (C2 segment) aneurysm (p = 0.022), prolonged PED deployment time more than 14.5 minutes (p = 0.005), and an acute angle of the anterior genu less than 51.5 degrees (p = 0.005) were risk factors in triggering CSR. CSR may be triggered during PED deployment under local anesthesia with mild sedation. Deployment to the C2 segment aneurysm, prolonged PED deployment time, and an acute angle of the anterior genu were associated with CSR triggering.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.