ArticleAdvanced functional materials2021
A HiPAD Integrated with rGO/MWCNTs Nano-Circuit Heater for Visual Point-of-Care Testing of SARS-CoV-2.
Article in Advanced functional materials, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Revolutionizing Healthcare With Paper-Based Nucleic Acid Testing.Exploration (Beijing, China) · 2026Review
- Recent Advances in Microfluidic Chip Technology for Laboratory Medicine: Innovations and Artificial Intelligence Integration.Biosensors · 2026Review
- Paper-Based Microfluidic Devices: A Powerful Strategy for Rapid Detection.Micromachines · 2025Review
- Advancements in nanobiosensor technologies for in-vitro diagnostics to point of care testing.Heliyon · 2024Review
- PCR Independent Strategy-Based Biosensors for RNA Detection.Biosensors · 2024Review
- Mapping the Nanotechnology Patent Landscape in the Field of Cancer.Recent patents on nanotechnology · 2024Article
- Star-shape non-fullerene acceptor featuring an aza-triangulene core for organic solar cells.Journal of materials chemistry. C · 2023Article
- Ultrafast Plasmonic Nucleic Acid Amplification and Real-Time Quantification for Decentralized Molecular Diagnostics.ACS nano · 2023Article
- Carbon-based nanomaterials against SARS-CoV-2: Therapeutic and diagnostic applications.OpenNano · 2023Article
- Tetrahedral DNA framework assisted rotational paper-based analytical device for differential detection of SARS-CoV-2 and influenza A H1N1 virus.Microchemical journal : devoted to the application of microtechniques in all branches of science · 2023Article
- The Emergence of Carbon Nanomaterials as Effective Nano-Avenues to Fight against COVID-19.Materials (Basel, Switzerland) · 2023Review
- Precise Design Strategies of Nanotechnologies for Controlled Drug Delivery.Journal of functional biomaterials · 2022Review
- CRISPR-Cas13a cascade-based viral RNA assay for detecting SARS-CoV-2 and its mutations in clinical samples.Sensors and actuators. B, Chemical · 2022Article
- Comparison of the Prevalence of Antibodies to SARS-CoV-2 in 9954 Recruits in the Korean Army Training Center with the General Korean Population of Equivalent Age Between September and November, 2020.Medical science monitor : international medical journal of experimental and clinical research · 2022Article
- Multifunctional carbon nanomaterials for diagnostic applications in infectious diseases and tumors.Materials today. Bio · 2022Review
- Microheater: material, design, fabrication, temperature control, and applications-a role in COVID-19.Biomedical microdevices · 2021Review
- A HiPAD Integrated with rGO/MWCNTs Nano-Circuit Heater for Visual Point-of-Care Testing of SARS-CoV-2.Advanced functional materials · 2021Article
- Rapid Detection of SARS-CoV-2 Using Duplex Reverse Transcription-Multienzyme Isothermal Rapid Amplification in a Point-of-Care Testing.Frontiers in cellular and infection microbiology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Nowadays, the main obstacle for further miniaturization and integration of nucleic acids point-of-care testing devices is the lack of low-cost and high-performance heating materials for supporting reliable nucleic acids amplification. Herein, reduced graphene oxide hybridized multi-walled carbon nanotubes nano-circuit integrated into an ingenious paper-based heater is developed, which is integrated into a paper-based analytical device (named HiPAD). The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is still raging across the world. As a proof of concept, the HiPAD is utilized to visually detect the SARS-CoV-2 N gene using colored loop-mediated isothermal amplification reaction. This HiPAD costing a few dollars has comparable detection performance to traditional nucleic acids amplifier costing thousands of dollars. The detection range is from 25 to 2.5 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials