Evidence map›Paper›PMID 34228140›Full record

ArticleJournal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie2022

Friction behavior of the wire material Gummetal®.

Isabel Eri Kopsahilis, Dieter Drescher

Open access · hybridAbstract read
In one paragraph

Article in Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 8 citations in OpenAlex.

  1. Load Deflection Characteristics of Orthodontic GummetalMaterials (Basel, Switzerland) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Isabel Eri KopsahilisDepartment of Orthodontics, University of Düsseldorf, Düsseldorf, Germany. klennerisabel@yahoo.com.ORCID http://orcid.org/0000-0002-3260-9043
Dieter DrescherDepartment of Orthodontics, University of Düsseldorf, Düsseldorf, Germany.
Heinrich Heine University Düsseldorf · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesGummetal® (Maruemu Works, Osaka, Japan), a new orthodontic wire material successfully used in clinical applications since 2006, is biocompatible and exhibits exceptionally high elasticity, nonlinear elastic behavior, plasticity and strength. Systematic comparisons of friction behavior are lacking; thus, the friction of Gummetal® in the binding modus was compared to commonly used low friction wires. MATERIALS AND

methodsIn vivo tests were run with Gummetal®, CoCr (cobalt-chromium Elgiloy®, Rocky Mountain Orthodontics, Denver, CO, USA), β‑Ti (β-Titanium TMA®, Ormco, Orange, CA, USA), NiTi (nickel-titanium, NiTi-SE, Dentalline, Birkenfeld, Germany), and stainless steel (SS; Ref. 251-925, 3M Unitek, Monrovia, CA, USA) [dimensions: 0.014 inch (0.35 mm), 0.016 inch (0.40 mm), 0.016 × 0.022 inch (0.40 × 0.56 mm), and 0.019 × 0.025 inch (0.48 × 0.64 mm)-β-Ti not available in the dimension 0.014 inch]. These were combined with Discovery® (Dentaurum, Ispringen, Germany), Micro Sprint® (Forestadent, Pforzheim, Germany), Clarity™ (3M Unitek), and Inspire Ice™ (Ormco) and slots in the dimension 0.022 inch (0.56 mm) and, except for the 0.019 × 0.025 inch wires, in the dimension 0.018 inch (0.46 mm). They were ligated with a 0.010 inch (0.25 mm) steel ligature (Smile Dental, Ratingen, Germany). Brackets were angulated by applying a moment of force of 10 Nmm against the wire, which was pulled through the slot at 0.2 mm/s.

resultsIn 660 tests using 132 bracket-wire combinations, friction loss for Gummetal® was comparable to and, in a few combinations with Micro Sprint®, significantly lower (p < 0.05) than SS and CoCr. The friction for Gummetal® was significantly lower (p < 0.05) than NiTi, and β‑Ti. In some bracket-wire combinations, lower friction was found with round wires compared to rectangular wires, except for the combination with Inspire Ice™, which was higher but not significant. Slot size did not have a significant effect on friction in most combinations.

conclusionThe low friction associated with Gummetal® wires during arch-guided tooth movement will be a valuable addition to the armamentarium of orthodontists.

Indexed as

Dental AlloysOrthodontic BracketsDental Stress AnalysisFrictionMaterials TestingOrthodontic Appliance DesignOrthodontic WiresTitaniumDental AlloysTitaniumIn vitro testsOrthodontic appliancesOrthodontic bracketsOrthodontic wiresTooth movement techniques

Identifiers

PMID34228140
PMCPMC8766389
OpenAlexW3178878559

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.