ArticleJournal of cancer research and clinical oncology2022
The first internal electromagnetic motion monitoring implementation for stereotactic liver radiotherapy in China: procedures and preliminary results.
Article in Journal of cancer research and clinical oncology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundRespiratory motion may compromise the dose delivery accuracy in liver stereotactic body radiation therapy (SBRT). Motion management can improve treatment delivery. However, external surrogate signal may be unstable and inaccurate. This study reports the first case of liver SBRT based on internal electromagnetic motion monitoring (Calypso, Varian Medical Systems, USA) in China. MATERIALS AND
methodsThe patient with a primary liver cancer was treated with respiratory-gated SBRT guided by three implanted electromagnetic transponders. The treatment was carried out in breath-hold end-exhale with beam-on when the centroid of the three transponders drifted within 5 mm (left-right (LR), anterior-posterior (AP) and cranio-caudal (CC) directions) from the planned position. The motion monitoring treatments were delivered in breath-hold end-exhale mode with the energy of 6 MV in FFF mode with 1200 monitor units (MU) per minute. For each fraction, QA results, intertransponder distances, geometric checks as well as tumor motion logs were explicitly recorded.
resultsComparing with the plan data, distance variances between each two transponders were - 0.56 ± 0.32 mm, 0.17 ± 0.33 mm and - 0.82 ± 0.68 mm. Geometric residual, the pitch, roll and yaw angles were 0.48 ± 0.21 mm (threshold 2.0 mm), 2.17° ± 1.85° (threshold 10°), - 2.42° ± 1.51° (threshold 10°) and 1.67° ± 1.07° (threshold 10°), respectively. The delivery time of the five fields were 13.8 s, 13.1 s, 11.2 s, 11.6 s, and 11.6 s with the average value of 12.3 ± 1.1 s. Treatment duration of each fraction ranged from 6.2 to 21.4 min, with the average value of 11.3 ± 5.0 min.
conclusionsThe first case of liver SBRT patient of China based on internal electromagnetic motion monitoring was performed. The system had a high tracking accuracy, and it did not delay the treatment time. In addition, the patient did not show any severe side effects except for grade I myelotoxicity. The internal electromagnetic motion monitoring system provides a real-time and direct way to track liver tumor targets.