ArticleThe Lancet. Microbe2021
Comparative performance of SARS-CoV-2 lateral flow antigen tests and association with detection of infectious virus in clinical specimens: a single-centre laboratory evaluation study.
Article in The Lancet. Microbe, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 89 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
89 citing papers in PubMed, 5 syntheses or guidelines pooled it, 154 citations in OpenAlex.
- Viral cultures, cycle threshold values and viral load estimation for assessing SARS-CoV-2 infectiousness in haematopoietic stem cell and solid organ transplant patients: a systematic review.The Journal of hospital infection · 2023Pooled it
- Assessing severe acute respiratory syndrome coronavirus 2 infectivity by reverse-transcription polymerase chain reaction: A systematic review and meta-analysis.Reviews in medical virology · 2022Pooled it
- Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection.The Cochrane database of systematic reviews · 2022Pooled it
- Accuracy of rapid point-of-care antigen-based diagnostics for SARS-CoV-2: An updated systematic review and meta-analysis with meta-regression analyzing influencing factors.PLoS medicine · 2022Pooled it
- Accuracy of novel antigen rapid diagnostics for SARS-CoV-2: A living systematic review and meta-analysis.PLoS medicine · 2021Pooled it
- Efficacy of Niclosamide vs Placebo in SARS-CoV-2 Respiratory Viral Clearance, Viral Shedding, and Duration of Symptoms Among Patients With Mild to Moderate COVID-19: A Phase 2 Randomized Clinical Trial.JAMA network open · 2022Trial
- Disentangling the drivers of heterogeneity in SARS-CoV-2 transmission from data on viral load and daily contact rates.PLoS computational biology · 2026Article
- Surfactant-free polymer microspheres with molecular confinement-enabled optical encoding for dual-color immunochromatographic assays.Mikrochimica acta · 2026Article
- Morphology-guided deep learning for nanoparticle agglomeration diagnostic assays.Scientific reports · 2026Article
- Informing optimal testing and isolation strategies across different stages of the diagnostic development pipeline using mathematical models: SARS-CoV-2 in the UK as a case study.BMJ public health · 2026Article
- Continuous and Scalable Production of Uniform Au Nanocrystals Capped by Citrate Species in Flow Reactors for Lateral Flow Tests.Small methods · 2025Article
- Estimating Antigen Test Sensitivity via Target Distribution Balancing: Development and Validation Study.JMIR bioinformatics and biotechnology · 2025Article
- Real-World Performance of COVID-19 Antigen Tests: Predictive Modeling and Laboratory-Based Validation.JMIRx med · 2025Article
- Quantum-enhanced nanodiamond rapid test advances early SARS-CoV-2 antigen detection in clinical diagnostics.Nature communications · 2025Article
- Laboratory evaluation of 185 commercial assays for detecting SARS-CoV-2: the UK response for mass testing.EClinicalMedicine · 2025Article
- Proteomics as a complementary approach to measure norovirus infection in clinical samples.Virology · 2025Review
- Article
- Multiplex lateral flow test sensitivity and specificity in detecting influenza A, B and SARS-CoV-2 in adult patients in a UK emergency department.Emergency medicine journal : EMJ · 2025Article
- Ultra-Sensitive Aptamer-Based Diagnostic Systems for Rapid Detection of All SARS-CoV-2 Variants.International journal of molecular sciences · 2025Article
- The ratio between SARS-CoV-2 RNA viral load and culturable viral titre differs depending on the stage of infection: a case study of household transmission in an adult male.Access microbiology · 2025Article
29 more citing papers are in PubMed but not listed here.
Corrections and comments
- Erratum issuedCorrection to2021
Authors and funding
21 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundLateral flow devices (LFDs) for rapid antigen testing are set to become a cornerstone of SARS-CoV-2 mass community testing, although their reduced sensitivity compared with PCR has raised questions of how well they identify infectious cases. Understanding their capabilities and limitations is, therefore, essential for successful implementation. We evaluated six commercial LFDs and assessed their correlation with infectious virus culture and PCR cycle threshold (Ct) values.
methodsIn a single-centre, laboratory evaluation study, we did a head-to-head comparison of six LFDs commercially available in the UK: Innova Rapid SARS-CoV-2 Antigen Test, Spring Healthcare SARS-CoV-2 Antigen Rapid Test Cassette, E25Bio Rapid Diagnostic Test, Encode SARS-CoV-2 Antigen Rapid Test Device, SureScreen COVID-19 Rapid Antigen Test Cassette, and SureScreen COVID-19 Rapid Fluorescence Antigen Test. We estimated the specificities and sensitivities of the LFDs using stored naso-oropharyngeal swabs collected at St Thomas' Hospital (London, UK) for routine diagnostic SARS-CoV-2 testing by real-time RT-PCR (RT-rtPCR). Swabs were from inpatients and outpatients from all departments of St Thomas' Hospital, and from health-care staff (all departments) and their household contacts. SARS-CoV-2-negative swabs from the same population (confirmed by RT-rtPCR) were used for comparative specificity determinations. All samples were collected between March 23 and Oct 27, 2020. We determined the limit of detection (LOD) for each test using viral plaque-forming units (PFUs) and viral RNA copy numbers of laboratory-grown SARS-CoV-2. Additionally, LFDs were selected to assess the correlation of antigen test result with RT-rtPCR Ct values and positive viral culture in Vero E6 cells. This analysis included longitudinal swabs from five infected inpatients with varying disease severities. Furthermore, the sensitivities of available LFDs were assessed in swabs (n=23; collected from Dec 4, 2020, to Jan 12, 2021) confirmed to be positive (RT-rtPCR and whole-genome sequencing) for the B.1.1.7 variant, which was the dominant genotype in the UK at the time of study completion.
findingsAll LFDs showed high specificity (≥98·0%), except for the E25Bio test (86·0% [95% CI 77·9-99·9]), and most tests reliably detected 50 PFU/test (equivalent SARS-CoV-2 N gene Ct value of 23·7, or RNA copy number of 3 × 10
interpretationIn this comprehensive comparison of antigen LFDs and virus infectivity, we found a clear relationship between Ct values, quantitative culture of infectious virus, and antigen LFD positivity in clinical samples. Our data support regular testing of target groups with LFDs to supplement the current PCR testing capacity, which would help to rapidly identify infected individuals in situations in which they would otherwise go undetected.
fundingKing's Together Rapid COVID-19, Medical Research Council, Wellcome Trust, Huo Family Foundation, UK Department of Health, National Institute for Health Research Comprehensive Biomedical Research Centre.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.