Evidence map›Paper›PMID 34224351›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2021

Deep Learning for Ultrasound Image Formation: CUBDL Evaluation Framework and Open Datasets.

Dongwoon Hyun, Alycen Wiacek, Sobhan Goudarzi, Sven Rothlubbers, Amir Asif, Klaus Eickel, Yonina C Eldar, Jiaqi Huang, Massimo Mischi, Hassan Rivaz and 4 more

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Migration of Deep Learning Models Across Ultrasound Scanners.IEEE transactions on bio-medical engineering · 2025
    Article
  8. Article
  9. Clinical, Safety, and Engineering Perspectives on Wearable Ultrasound Technology: A Review.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Lung Sonography in Critical Care Medicine.Diagnostics (Basel, Switzerland) · 2022
    Review
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Dongwoon Hyun
Alycen Wiacek
Sobhan Goudarzi
Sven Rothlubbers
Amir Asif
Klaus Eickel
Yonina C Eldar
Jiaqi Huang
Massimo Mischi
Hassan Rivaz
David Sinden
Ruud J G van Sloun
Hannah Strohm
Muyinatu A Lediju Bell

Funding

A Machine Learning Alternative to Beamforming to Improve Ultrasound Image Quality for Interventional Access to the KidneyR21EB025621 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI BELL, MUYINATU A. LEDIJU · 2018 to 2021
$859k
NIBIB NIH HHS R21 EB025621
6 · The paper itself

Abstract

Deep learning for ultrasound image formation is rapidly garnering research support and attention, quickly rising as the latest frontier in ultrasound image formation, with much promise to balance both image quality and display speed. Despite this promise, one challenge with identifying optimal solutions is the absence of unified evaluation methods and datasets that are not specific to a single research group. This article introduces the largest known international database of ultrasound channel data and describes the associated evaluation methods that were initially developed for the challenge on ultrasound beamforming with deep learning (CUBDL), which was offered as a component of the 2020 IEEE International Ultrasonics Symposium. We summarize the challenge results and present qualitative and quantitative assessments using both the initially closed CUBDL evaluation test dataset (which was crowd-sourced from multiple groups around the world) and additional in vivo breast ultrasound data contributed after the challenge was completed. As an example quantitative assessment, single plane wave images from the CUBDL Task 1 dataset produced a mean generalized contrast-to-noise ratio (gCNR) of 0.67 and a mean lateral resolution of 0.42 mm when formed with delay-and-sum beamforming, compared with a mean gCNR as high as 0.81 and a mean lateral resolution as low as 0.32 mm when formed with networks submitted by the challenge winners. We also describe contributed CUBDL data that may be used for training of future networks. The compiled database includes a total of 576 image acquisition sequences. We additionally introduce a neural-network-based global sound speed estimator implementation that was necessary to fairly evaluate the results obtained with this international database. The integration of CUBDL evaluation methods, evaluation code, network weights from the challenge winners, and all datasets described herein are publicly available (visit https://cubdl.jhu.edu for details).

Indexed as

Deep LearningImage Processing, Computer-AssistedNeural Networks, ComputerPhantoms, ImagingUltrasonography

Identifiers

PMID34224351
PMCPMC8818124

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.