ArticleJournal of veterinary internal medicine2021
Validation of a flash glucose monitoring system in outpatient diabetic cats.
Article in Journal of veterinary internal medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 96 citations in OpenAlex.
- iCatCare 2025 consensus guidelines on the diagnosis and management of diabetes mellitus in cats.Journal of feline medicine and surgery · 2025Guideline
- Evaluating the correlation between serum fructosamine concentration and interstitial glucose concentration in cats with diabetes mellitus.Journal of veterinary internal medicine · 2026Article
- Nutrition Research in Aging Dogs and Cats: What We Know and What We Need to Do.Animals : an open access journal from MDPI · 2026Review
- Evaluation of the Accuracy of FreeStyle Libre 2 for Glucose Monitoring in White New Zealand Rabbits.Veterinary medicine and science · 2025Article
- Comparison between a Flash Glucose Monitoring System and a Portable Blood Glucose Meter for Monitoring of Cats with Diabetic Ketosis or Ketoacidosis.Animals : an open access journal from MDPI · 2024Article
- A concept for human use of real-time and remote monitoring of diabetic subjects using intermittent scanned continuous glucose measurement.Biomedical engineering online · 2024Article
- Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus.Journal of feline medicine and surgery · 2022Article
- Clinical Use of a 180-Day Implantable Glucose Monitoring System in Dogs with Diabetes Mellitus: A Case Series.Animals : an open access journal from MDPI · 2022Article
- Validation of a flash glucose monitoring system in outpatient diabetic cats.Journal of veterinary internal medicine · 2021Article
- Accuracy of the Freestyle Libre 3 Continuous Glucose Monitoring System in Hypo- and Euglycemic Cats.Journal of veterinary internal medicineArticle
- Assessment of the FreeStyle Libre 2 interstitial glucose monitor in hypo- and euglycemic cats.Journal of veterinary internal medicineArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundInterstitial glucose (IG) concentration measurement using a flash glucose monitoring system (FGMS) is a noninvasive, affordable, and informative method to regulate patients with diabetes mellitus (DM) but has not been fully validated in outpatient cats with DM.
objectivesTo further validate the FreeStyle Libre FGMS in outpatient diabetic cats. ANIMALS: Eight client-owned cats with DM.
methodsProspective observational validation study. Tissue glue was used to attach the sensor to the cat. Lin's concordance correlation coefficient (ρ
resultsData from 15 sensor placements in 8 cats were analyzed. Paired IG and ABA glucose concentrations (139 samples) had excellent correlation (ρ CONCLUSIONS AND CLINICAL IMPORTANCE: In outpatient cats with DM, the FGMS-measured IG concentration correlated well with ABA-measured blood glucose concentration, but a high rate of sensor failures was observed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.