Evidence map›Paper›PMID 34223387›Full record

ArticleResuscitation plus2021

The impact of introducing real time feedback on ventilation rate and tidal volume by ambulance clinicians in the North East in cardiac arrest simulations.

Karl Charlton, Graham McClelland, Karen Millican, Daniel Haworth, Paul Aitken-Fell, Michael Norton

Open access · goldAbstract read
In one paragraph

Article in Resuscitation plus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Karl CharltonNorth East Ambulance Service NHS Foundation Trust, Bernicia House, Newburn Riverside, Newcastle upon Tyne NE15 8NY, UK.
Graham McClellandNorth East Ambulance Service NHS Foundation Trust, Bernicia House, Newburn Riverside, Newcastle upon Tyne NE15 8NY, UK.
Karen MillicanNorth East Ambulance Service NHS Foundation Trust, Bernicia House, Newburn Riverside, Newcastle upon Tyne NE15 8NY, UK.
Daniel HaworthNorth East Ambulance Service NHS Foundation Trust, Bernicia House, Newburn Riverside, Newcastle upon Tyne NE15 8NY, UK.
Paul Aitken-FellNorth East Ambulance Service NHS Foundation Trust, Bernicia House, Newburn Riverside, Newcastle upon Tyne NE15 8NY, UK.
Michael NortonNorth East Ambulance Service NHS Foundation Trust, Bernicia House, Newburn Riverside, Newcastle upon Tyne NE15 8NY, UK.
North East Ambulance Service NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundResearch suggests rescuers deliver ventilations outside of recommendations during out of hospital cardiac arrest (OHCA), which can be deleterious to survival. We aimed to determine if ambulance clinician compliance with ventilation recommendations could be improved using the Zoll Accuvent real time ventilation feedback device (VFD).

methodsParticipants simulated a two-minute cardiac arrest scenario using a mannequin and defibrillator without ventilation feedback. Eligible for inclusion were all clinicians aged ≥18 years who perform cardiopulmonary resuscitation (CPR) as part of their role, who had completed an internal advanced life support (ALS) refresher. Following familiarisation of a few minutes with the VFD, participants repeated the two-minute scenario with ventilation feedback. Ventilation rate and volume and CPR quality were recorded. Primary outcome was % difference in ventilation compliance with and without feedback. Secondary outcomes were differences between paramedic and non-paramedic clinicians and compliance with chest compression guidelines.

resultsOne hundred and six participants completed the study. Median ventilation rate without feedback was 10 (IQR 8-14, range 4-30) compared to 9 (IQR 9-9, range 6-17) with feedback; median tidal volume without feedback was 630 mls (IQR 518-725, range 201-1114) compared to 546 mls (IQR 531-560, range 490-750) with feedback. Proportion of clinicians ≥50% compliant with European Resuscitation Council ventilation recommendations were significantly greater with ventilation feedback compared to without, 91% vs. 9%, (McNemars test

conclusionsAmbulance clinician baseline ventilation quality was frequently outside of recommendations, but a VFD can ensure treatment is within evidence-based recommendations. Further research is required to validate the use of the VFD in true clinical practice and to evaluate the relationship between improved ventilation quality during OHCA and patient outcomes.

Indexed as

Manual ventilationOut of hospital cardiac arrestRespiratory rateSimulationTidal volume

Identifiers

PMID34223387
PMCPMC8244525
OpenAlexW3157496694

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.