Evidence map›Paper›PMID 34221326›Full record

ArticleChemical science2021

Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs.

Ya-Ling Tan, A-Qian Huang, Li-Juan Tang, Jian-Hui Jiang

Open access · diamondAbstract read
In one paragraph

Article in Chemical science, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 35 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. StratoLAMP: Label-free, multiplex digital loop-mediated isothermal amplification based on visual stratification of precipitate.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Cell-Free Production Systems in Droplet Microfluidics.Advances in biochemical engineering/biotechnology · 2023
    Review
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Ya-Ling TanState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University Changsha 410082 P. R. China jianhuijiang@hnu.edu.cn tanglijuan@hnu.edu.cn +86-731-88822577 +86-731-88822872.
A-Qian HuangState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University Changsha 410082 P. R. China jianhuijiang@hnu.edu.cn tanglijuan@hnu.edu.cn +86-731-88822577 +86-731-88822872.
Li-Juan TangState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University Changsha 410082 P. R. China jianhuijiang@hnu.edu.cn tanglijuan@hnu.edu.cn +86-731-88822577 +86-731-88822872.
Jian-Hui JiangState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University Changsha 410082 P. R. China jianhuijiang@hnu.edu.cn tanglijuan@hnu.edu.cn +86-731-88822577 +86-731-88822872.ORCID https://orcid.org/0000-0003-1594-4023
Hunan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Highly sensitive digital nucleic acid techniques are of great significance for the prevention and control of epidemic diseases. Here we report the development of multiplexed droplet loop-mediated isothermal amplification (multiplexed dLAMP) with scorpion-shaped probes (SPs) and fluorescence microscopic counting for simultaneous quantification of multiple targets. A set of target-specific fluorescence-activable SPs are designed, which allows establishment of a novel multiplexed LAMP strategy for simultaneous detection of multiple cDNA targets. The digital multiplexed LAMP assay is thus developed by implementing the LAMP reaction using a droplet microfluidic chip coupled to a droplet counting microwell chip. The droplet counting system allows rapid and accurate counting of the numbers of total droplets and the positive droplets by collecting multi-color fluorescence images of the droplets in a microwell. The multiplexed dLAMP assay was successfully demonstrated for the quantification of HCV and HIV cDNA with high precision and detection limits as low as 4 copies per reaction. We also verified its potential for simultaneous digital assay of HCV and HIV RNA in clinical plasma samples. This multiplexed dLAMP technique can afford a useful platform for highly sensitive and specific detection of nucleic acids of viruses and other pathogens, enabling rapid diagnosis and prevention of infectious diseases.

Identifiers

PMID34221326
PMCPMC8221175
OpenAlexW3162628857

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.