ArticleJournal of diabetes science and technology2022
The Accuracy of Continuous Glucose Monitoring in the Medical Intensive Care Unit.
Article in Journal of diabetes science and technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 32 citations in OpenAlex.
- Using technology to support diabetes care in hospital: Guidelines from the Joint British Diabetes Societies for Inpatient Care (JBDS-IP) group and Diabetes Technology Network (DTN) UK.Diabetic medicine : a journal of the British Diabetic Association · 2025Guideline
- Pediatric Inpatient Continuous Glucose Monitor Accuracy by Sensor Wear Day, Hospital Day, and Glucose Rate of Change.Diabetes technology & therapeutics · 2026Article
- Accuracy of continuous glucose monitoring in critically ill patients.Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine · 2025Article
- Dexcom G7 Accuracy and Reproducibility in the Intensive Care Unit.Diabetes technology & therapeutics · 2025Article
- Clinical trial protocol for continuous glucose monitoring in critical care at Hospital Clinic of Barcelona (CGM-UCI23).Nursing in critical care · 2025Article
- Prospective Study on Self-Calibrating Continuous Glucose Monitoring Practicality and Accuracy in Noncritically Ill COVID-19 Hospitalized Patients.Journal of diabetes research · 2025Article
- Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review.Intensive care medicine · 2024Article
- Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions.Diabetes technology & therapeutics · 2024Article
- Accuracy of a Continuous Glucose Monitor During Pediatric Type 1 Diabetes Inpatient Admissions.Diabetes technology & therapeutics · 2024Article
- A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials.Journal of diabetes science and technology · 2023Article
- Continuous glucose monitoring for inpatient diabetes management: an update on current evidence and practice.Endocrine connections · 2023Review
- Continuous Glucose Monitoring in the Intensive Care Unit.Journal of diabetes science and technology · 2023Article
- Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care.Journal of diabetes science and technology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo assess the accuracy of continuous glucose monitoring (CGM) in medical intensive care unit (MICU) patients.
methodsA Medtronic Enlite
resultsUsing CBG as a reference, MARD was 6.6%. Overall, 99.7% of the CGM readings were within the "no risk" zone. No significant differences in accuracy were seen within vasopressor subgroups. Using PG as the reference, MARD was 8.8%. The surveillance error grid analysis showed 95.2% of glucose readings were within the "no risk" zone. There were no device-related adverse events.
conclusionThe CGM sensor showed acceptable accuracy in MICU patients, regardless of vasopressor use.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials